15
INDICATION OF QUICK CHARGER LAMPS
∗
For batteries those are at low temperatures (10°C (50°F) or lower), charging time must be extended
longer.
Charger LED lamp
Buzzer sound
Recharging status
Red lamp blinks.
The power cord is plugged
into the receptacle.
Two short beeps (Pi, pi)
The charger is
powered.
The charger power cord is plugged
into a wall socket.
Red lamp lights.
The battery pack is mounted.
One short beep (Pi)
The battery is be-
ing recharged.
Quick recharging continues.
The green lamp blinks.
The battery has been re-
charged.
A long beep for approx. 2
seconds (Piii...)
The battery has
been recharged.
The battery has been recharged to ap-
prox. 90% of its capacity.
If you leave the battery pack on the
charger, recharging will continue.
The green lamp lights up.
Fully recharged.
A long beep for approx. 2
seconds (Piii...)
Battery is "fully" re-
charged.
Recharged to 100% capacity.
The red lamp lights up.
The orange lamp lights up.
—
Protective charging
The battery is recharged with a low
current to protect the charger and bat-
tery.
The orange lamp lights up.
—
Standby
If the temperature of the battery pack
is too high: Battery recharging starts
automatically when the tem-perature
drops below the limit.
If the temperature of the battery pack
is too low: Place the battery pack in a
room temperature location for a while,
then retry recharging it.
The orange lamp blinks.
Not possible to recharge.
Short continuous beeps for
approx. 10 seconds
(Pi, pi, pi, pi,...)
Not possible to re-
charge.
Unable to recharge the battery.
The battery pack slot is contaminated,
or the battery pack has failed.
For the JC928 lithium ion battery charger (CE)
"Power Supply Cord: Use UL Listed and CSA Certified detachable power supply cord, 18 AWG, two
conductors, cord rated VW-1, 105°C, cord external length minimum 1.8m.
One end terminates in a molded-on attachment plug with a 15 A, 125 V (NEMA 1-15P) or 15 A, 250
V (NEMA 2-15P) type configuration.
Other end terminates in a molded-on connector which mates with the Power Appliance Inlet.
If a flexible power supply cord is required, the appropriate cord (see below) must be used.
The SP-2, SPE-2, SV, SVE, or SVT flexible power supply cord can be used."
It blinks every second.
It remains lit.
It blinks every second.
It remains lit.
They remain lit.
It blinks every second.
It blinks quickly (0.1 sec
ON and 0.1 sec OFF).
PJR265_CE.book 15 ページ 2010年10月13日 水曜日 午後4時51分