TROUBLESHOOTING
10 - 9
D-MAXE with OI-B/OI-N
www.maxcessintl.com
MI 2-296 1 D
Feh
lersu
che
.fm
Faulty behavior
and
setting errors
Often the cause of incorrect or undesirable guiding behavior is
an incorrect setting on the D-MAXE system. These errors can
easily be eliminated by changing the appropriate settings on the
D-MAXE system.
Possible causes for faulty
D-MAXE behavior
Errors caused by connections or settings on the D-MAXE system
can result in many kinds of faulty behavior in the system. Often
it is difficult to deduce the cause directly from a faulty behavior.
You should therefore check the possible causes in the following
table and eliminate any that are present.
Possible causes for faulty
behavior
Remedy
Reference
No response on the
desired actuator.
Wrong actuator selected?
Select "Manual mode" and
check whether the correct
actuator is selected.
Selection of "devices", page 4-
"(*)" appears before the
menu identification.
Remote control is turned
off
Remote control is turned on.
Remote control must be turned
on to ensure complete
operation.
Is activation by means of
the digital inputs possible?
Check the digital inputs.
see item
section
Is activation by means of a
fieldbus possible (e.g.
Profibus) ?
Check the fieldbus status.
see
Check the fieldbus data.
see
For more information about
fieldbus data, refer to the
"Supplementary Operating
Instructions" in the system
documentation.
Are the digital outputs
being used?
Check the status (set/deleted)
of the digital outputs.
see
in section