INSTALLATION
3 - 6
D-MAXE with OI-B/OI-N
www.maxcessintl.com
MI 2-296 1 D
Electrical connection
CAUTION:
Electrical connections on the D-MAXE system should always be
made or disconnected while there is no electrical power in the
system.
Failure to follow these instructions may result in damage to the
D-MAXE system.
Emergency Stop
Observe the “D-MAX Supplementary Operating Instructions -
Safe shutoff of electromechanical actuators driven by a D-MAX
or D-MAXE Controller” in the system documentation.
Power supply of D-MAXE
Controller
The D-MAXE Controller has no power switch. Because of this,
the power supply of the D-MAXE Controller
must be switched on
and off via the machine's power distribution.
The D-MAXE Controller must be connected to the power supply
according to the information supplied at connector X6 of the
controller (see
and
).
Power supply of D-MAX
operator interface OI-B or
OI-N
D-MAX operator interfaces OI-B and OI-N are connected to a
power supply (see
Connecting the sensors/
actuators
– Only sensors and actuators approved by Maxcess may be
used.
– The technical data for sensors and actuators must match the
connection data for the D-MAXE system (see
).
– Relevant operating instructions must be observed for
installation and operation of sensors and actuators.
– Sensors and actuators must be connected to the D-MAXE
system according to the system diagram in the system
documentation.