5-1
DIGITAL INPUT/OUTPUT MATRIX
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
Digital Input Matrix
INPUTS
MODE
5
4
3
2
1
0
EXTERNAL LOCK
-
-
-
-
-
1
AUTOMATIC
-
-
0
0
1
-
MANUAL
-
-
0
1
0
-
SERVO-CENTER
-
-
1
0
0
-
JOG Minus *
0
1
-
-
-
-
JOG Plus *
1
0
-
-
-
-
RGPC Minus *
0
1
-
-
-
-
RGPC Plus *
1
0
-
-
-
-
RGPC RESET *
1
1
-
-
-
-
Sensor S1 (Single Edge Guiding) **
-
-
0
1
1
-
Sensor S2 (Single Edge Guiding) **
-
-
1
1
0
-
Sensor S1 – S2 (Center-guiding) **
-
-
1
1
1
-
* Inputs 4 & 5 are used to provide Jogs while in Manual and Servo Center modes, and RGPC
functions while in Automatic mode.
** Sensor selection is allowed in Manual and Servo Center modes, only. Sensor selection
must be momentary commands.
0 = LOW
1 = HIGH
- = IGNORE
Note: To ensure that a command is properly executed, all pertinent inputs for each
command must be switched high or low within 20 mS of each other and maintained for at
least 30 mS.
WARNING – Death or injury can result from unexpected movement.
Auto setup operation causes guide movement. Take appropriate precautions to
ensure no one is in the vicinity of the guide path of travel.