2-3
FEATURES
www.maxcessintl.com
Fife GMA-BL
MI 2-264 1 B
Button functions and definitions
The table below gives the name along with an operational function description of each
button displayed on the operator interface.
AUTOMATIC This button initiates the Automatic mode. Correction
is applied to the web by moving the actuator in response to the
output of the sensor(s) that have been selected.
SERVO-CENTER This button initiates the Servo-Center mode. The
actuator is centered in its travel in response to the output of the
internal Servo-Center transducer.
MANUAL This button initiates the Manual mode. No correction is
applied to the actuator.
SENSOR This button is used to select the sensor(s) to be used for
monitoring the web position when the system is in Automatic mode.
Sensor selection is allowed in Manual and Servo-Center modes only.
SETUP This button is used to enter the Setup Menus for configuring
and adjusting the guiding system.
ARROWS These buttons are used to jog the actuator. The direction
of actuator movement is configurable.
GUIDE POINT ADJUST The two arrow buttons near the bar graph are
used to adjust the System Guide Point while in Automatic Mode or
Manual Mode. The button in the center is used to reset the System
Guide Point to the default value, which is 50% of the sensor
bandwidth.