OPERATION
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 19 of 67
4.0
Operation
There are four control buttons on the DLCA NET-S1.
[+] = increment
[-] = decrement
[
] = enter or save function*
[
n
] = zero the displayed tension
(the zero button)
* For clarity, these instructions use the word [ENTER] instead of the symbol [
].
Power on
The DLCA NET-S1 will display the software version number
when power is first applied for five seconds and then the DLCA
NET-S1 will start displaying the tension. During the software
version display, diagnostics are performed on the load cells
and any errors are displayed.
The load cell diagnostic errors are shown in Table 1.
To exit from the load cell diagnostic error
-
Press [Enter] and the tension will be displayed.
-
The error display will be canceled after 45 seconds and
then tension will be displayed.
-
If no errors are detected, the tension will be displayed.
Display
Meaning
Sensor 1
Sensor 2
Er 1
Sensor 1 White (S+) or Black (S-) wire
disconnected.
Good
Er 2
Sensor 1 Red (P+) wire disconnected.
Good
Er 3
Sensor 1 Green (P-) wire disconnected. Good
Er 4
Sensor 1 Failure or other wiring error.
Example: Green and White wire are
swapped, etc.
Good
Er 8
Good
Sensor 2 White (S+) or Black (S-) wire
disconnected.
Er 9
Sensor 1 White (S+) or Black (S-) wire
disconnected.
Sensor 2 White (S+) or Black (S-) wire
disconnected.
Er 10
Sensor 1 Red (P+) wire disconnected.
Sensor 2 White (S+) or Black (S-) wire
disconnected.
Er 11
Sensor 1 Green (P-) wire disconnected. Sensor 2 White (S+) or Black (S-) wire
disconnected.