PARAMETERS
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 36 of 67
7.4
Miscellaneous parameters
Parameter Description
Default
P.05
Decimal Point Position, Tension Zone 1
Set the decimal point position to show when displaying tension.
0 = 000000
1 = 000000.
2 = 00000.0
3 = 0000.00
4 = 000.000
5 = 00.0000
6 = 0.00000
0
P.06
Tension Polarity, Tension Zone 1
Set to -1 to show positive tension when the force is acting in the
direction opposite the force direction arrow on the load cells. Set
automatically by Precision calibration.
0 = -1,
1 = +1
+1
P.07
Decimal Point Position, Tension Zone 2
Set the decimal point position to show when displaying tension.
0 = 000000
1 = 000000.
2 = 00000.0
3 = 0000.00
4 = 000.000
5 = 00.0000
6 = 0.00000
0
P.08
Tension Polarity, Tension Zone 2
Set to -1 to show positive tension when the force is acting in the
direction opposite the force direction arrow on the load cells. Set
automatically by Precision calibration.
0 = -1
1 = +1
+1