CALIBRATE TENSION USING KEYPAD
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 27 of 67
Precision calibration continued
Channel 1 and 2:
Press and hold [+] and [-] for two seconds to enter programming
mode.
Use [+] and/or [-] to go to parameter CAL3.1. Press [Enter] to enter
the sub-menu.
Display now shows C31.1. Apply the calibration roll weight to
channel 1 and calibration tension to channel 2 and Press [Enter]. The
DLCA NET-S1 will now create a ratio of tension seen by channel 1
and channel 2 and show a wait display. When calibration is complete
the DLCA NET-S1 will display PASS for successful calibration or an
error code to indicate an issue with the calibration. Press [Enter] to
return to tension display.
Precision calibration procedure is now complete.
To resolve errors, refer to Table 2 on page 28.
LC1 - Roll Weight load cells on channel 1.
LC2 - Web Tension Load Cells on channel 2.
RW - Roll Weight
T - Web Tension
Figure 7. Apply calibration tension