11.0
SCREEN DEFINITIONS, ALPHABETICAL LIST
www.maxcessintl.com
MAGPOWR Spyder-Plus-S1 Tension Control
MI 850A351 1 C
Page 54 of 68
Retune P at core.
Part of
Quick Stabilize
on unwinds or on rewinds. This screen
appears when Quick Stabilize has stabilized the system while P is
being adjusted. If the present diameter is not the core diameter,
retune P when the system is at core.
Rarely, the system will be more stable at core than at some other
diameter. Retuning at core will then cause the system to be unstable
again when the less stable diameter is reached. In this case retune at
the less stable diameter rather than at core.
Retune P now.
Part of
Quick Stabilize
on point to point systems. This screen
appears when Quick Stabilize has stabilized the system while P is
being adjusted. Immediately retune P.
Roll Weight
From the Inertia Setup menu for Load Cell systems. Enter the full roll
weight for use in inertia setup.
Roll Width
From the
Parameters
menu. Sets the current roll width to be used in
the inertia compensation calculation for load cells.
From the
Inertia Setup
menu. Sets the roll width for the inertia setup
parameters.
Screen Contrast
From the
Configure
menu.
Used to adjust the screen contrast. Use
and
to adjust.
Secondary tuning is optimal
From the
Tuning
menu for point to point systems.
This screen announces that Proportional Gain has been increased to
the maximum allowed during tuning (50). Proportional Gain can be
set higher than this using the
Parameters
menu, but that is not
recommended.
Secondary tuning is optimal.
From Cal Sensors menu for point to point systems.
Informs the operator that the most aggressive value allowed for
secondary manual tuning has been reached. Secondary tuning
should only be performed after primary tuning is optimized.
Security Code
From the
Security
menu.
Use to enter the security code to secure or unsecure the Spyder.
When secured only Remote Setpoint Tension and Percent Taper can
be changed.
Security Secured
Or
Security Not Secured
One of the top level menu screens. This screen also displays the
present state of security. When secured only Remote Setpoint
Tension and Percent Taper can be changed.
Sensing Roll is too heavy.
A load cell calibration error message.
See Load Cell Calibration
Problems
in Section 10.4.
Setpoint Tension
In the
Operator Loop
.
This is a display only of the tension setpoint. The tension setpoint is
set by either the Tension Input (Term.16 to Term.17) or by the
Ethernet connection. The source of the setpoint tension is determined
by Setpoint Source in the Configure menu.
Setpoint Tension
In the
Operator Loop
without taper tension
This is a display only of the tension setpoint. The tension setpoint is
set by either the Tension Input (Term.16 to Term.17) or by the
Ethernet connection. The source of the setpoint tension is determined
by Setpoint Source in the Configure menu.