COMMISSIONING OF DP-20/DP-30
3 - 4
SE-46C
Commissioning of the web guide controllers
www.maxcess.eu
MI 1071 1 A
Inbetriebnahme
DP-2
030.fm
OI-TS operator interface:
∙
Select signal assignment 10mA
DP-20/DP-30 web guide controller:
∙
Determine the second reference value
∙
Press the ENTER key
The DP-20/DP-30 web guide controller returns to the user area
if the calibration was successful.
1.5. Exit menu 1K.8.3
Simulate Analog Signals
on
the SE-46C
OI-TS operator interface:
∙
Press the CONFIRMATION button to exit menu 1K.8.3
∙
Press the RETURN button twice to return to the operator level
2. Setting the ASC
(Automatic Sensor Control)
2.1. Selecting the ASC Source DP-20/DP-30 web guide controller:
∙
DP-20 controller: select menu 3D.5.3
DP-30 controller: select menu 3D.5.4
(Manual
Custom
ASC Source)
∙
As
ASC source
select Line sensor - Line edge
§
2.2. Setting ASC limits
DP-20/DP-30 web guide controller:
∙
DP-20 controller: select menu 3D.5.2
DP-30 controller: select menu 3D.5.3
(Manual
Custom
ASC Limits)
∙
Set the values of the
ASC limits
to the range from
-90%
to
+90%
G