COMMISSIONING OF FIFE-500
4 - 5
SE-46C
Commissioning of the web guide controllers
www.maxcess.eu
MI 1071 1 A
Inbetr
iebna
hme Fife-500.fm
∙
Set ASC Threshold 1 (Pos) to 29490
∙
Set ASC Threshold 2 (Neg) to -29490
∙
Press the ACCEPT
button to exit menu
∙
Press ASC ON button
The "ASC ON" symbol appears in the menu header and in
the operator level
3. Setting the polarity and
gain
Note:
Settings must be made for sensor mode E - Line centre
ý
(S2).
3.1. Setting the polarity
The guiding direction (polarity) must be checked depending on
the mechanical installation direction of the system and adjusted
if necessary.
FIFE-500 operator interface:
∙
Select menu
1E.2.1
(Press Setup button
Press Right Arrow button
Press
Guide Settings
button)
∙
Set the
polarity
for S2
∙
Press the ACCEPT
button to exit menu
3.2. Setting the gain
The gain must be set optimally.
FIFE-500 operator interface:
∙
Select menu 1E.1.6.
(Press Setup button
Press Gain button)
∙
Set the
gain
∙
Press the ACCEPT
button to exit menu
Operation
Note:
The FIFE-500 web guide controller must be operated in
„Automatic“ mode with sensor mode E - Line centre
ý
(S2).