60
61
MAXDATA SN 40 M1 – User Guide
Managing Your Storage System
60
61
MAXDATA SN 40 M1 – User Guide
Managing Your Storage System
Replacing a Hard Disk
The MAXDATA SN 40 Storage System allows for easy installation and replacement of hard disks for
any upgrade or repair.
Important
Either a plastic retention device or a hard drive must be installed in each drive carrier and all four
drive carriers must be installed in the storage system during operation. There will be inadequate drive
cooling if any drive bays are left open.
Caution
Before performing any maintenance on the system, back up the data. Shut down the storage system by
selecting the “Advanced” tab from the Manager and then “Shutdown” from the left-hand menu.
1. Observe all safety and ESD precautions listed in Chapter 1, “Safety and Warnings”.
2. If you are unable to shut down the system using the software Manager then power down the
storage system by pressing and holding the power button for approximately five seconds until
the System Status LED starts flashing. The storage system will shut off after a short shutdown
period.
3. Disconnect the storage system from its power source.
4. Press in the green latch at the end of the drive carrier to disengage the drive carrier from the
storage system. Pull out on the black lever (see letter “B”) to pull the drive carrier partially out
of the storage system. Slide the drive carrier all the way out of the storage system.
Figure 29. Removing Drive Carrier from Storage System
4
3
2
1
1