41
c) Buzzer Alarm – switches the alarm on and off. The alarm function
makes a beep sound as a reminder whenever the data reading
reaches the preset minimum or maximum point.
To set threshold limits for the parameter values
1. Tap the
Setting
functional button at the bottom of the Live Data
screen.
2. Tap the
Selected
navigation button.
3. Select a parameter item on the left column, or enter the item name
in the Search bar.
4. Tap on the right side of the
MIN
button, and enter the required
minimum value.
5. Tap on the right side of the
MAX
button, and enter the required
maximum value.
6. Tap the
ON/OFF
button on the right side of the Buzzer Alarm
button to turn it on or off.
7. Tap
Done
to save the setting and return to the Live Data screen; or
tap
Cancel
to exit without saving.
If the threshold limits are successfully set, two horizontal lines will appear on
each of the data graphs (when Waveform Graph Mode is applied) to
indicate the alarming point. The threshold lines are shown in different colors
from the waveform of the parameters for distinction.
Record Button – displays the configuration screen for Record Setting,
on which you can set the trigger type, duration and trigger point for the
data recording function.
a) Trigger Type – sets the trigger mode for data recording, mainly of
two kinds: Manual and Auto. There are four options available:
1) Manual – allows you to manually start and stop data recording.
2) DTC – auto triggers data recording when any DTC is detected.
3) DTC Check Mode – auto triggers data recording when certain
pre-selected DTC types are detected.
4) Parameter – auto triggers data recording when any parameter
value reaches the preset threshold.
b) Duration – sets the recording time (for Auto trigger mode only).
c) Trigger Point – reserves a relative percentage of a record length
Summary of Contents for MX808TS
Page 80: ...73 Figure 5 30 Sample IMMO Note Screen Figure 5 31 Sample Program Key FOB Screen ...
Page 83: ...76 Figure 6 2 Sample Vehicle Manufacturer Selection Figure 6 3 Sample Vehicle Model Selection ...
Page 128: ...121 Programmer Update Coming soon ...