MAX32600 User’s Guide
System Configuration and Management
4.1 Power Ecosystem and Operating Modes
PWRSEQ_MSK_FLAGS.rtc_rollover
Field
Bits
Default
Access
Description
rtc_rollover
16
0
R/W
Mask for RTC rollover event
• 0: Event can be detected
• 1: Event is masked
PWRSEQ_MSK_FLAGS.pwr_brownout_det
Field
Bits
Default
Access
Description
pwr_brownout_det
17
1
R/W
Mask for power brownout detect
Note
Masked by default
• 0: Event can be detected
• 1: Event is masked
PWRSEQ_MSK_FLAGS.pwr_usb_plug_wakeup
Field
Bits
Default
Access
Description
pwr_usb_plug_wakeup
18
0
R/W
Mask
for
USB
power
connected
wakeup event
• 0: Event can be detected
• 1: Event is masked
Rev.1.3 April 2015
Maxim Integrated