MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.1 System Clock
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
CLKMAN_CLK_GATE_CTRL0.apb_bridge_clk_gater
Field
Bits
Default
Access
Description
apb_bridge_clk_gater
11:10
01b
R/W
Clock Gating Control for AHB-to-APB
Bridge
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
CLKMAN_CLK_GATE_CTRL0.sysman_clk_gater
Field
Bits
Default
Access
Description
sysman_clk_gater
13:12
01b
R/W
Clock
Gating
Control
for
Clkman/
−
Pwrman/IOman
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
Rev.1.3 April 2015
Maxim Integrated
Page 542