MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.3 Real Time Clock (RTC)
Field
Bits
Default
Access
Description
set_active
20
s
R/O
timer_set_active
This sync transaction with the 4kHz clock domain occurs when a new timer value is written to the
register.
Reads 1 when the associated transaction is pending.
RTCTMR_CTRL.clr_active
Field
Bits
Default
Access
Description
clr_active
21
s
R/O
timer_clr_active
Reads 1 when the associated transaction is pending
RTCTMR_CTRL.rollover_clr_active
Field
Bits
Default
Access
Description
rollover_clr_active
22
s
R/O
rollover_clr_active
Reads 1 when the associated transaction is pending
RTCTMR_CTRL.prescale_cmpr0_active
Field
Bits
Default
Access
Description
prescale_cmpr0_active
23
s
R/O
prescale_cmpr0_active
Reads 1 when the associated transaction is pending
Rev.1.3 April 2015
Maxim Integrated
Page 572