MAX32600 User’s Guide
Communication Peripherals
7.4 USB Device Interface
USB_EP.ep_buf2
Field
Bits
Default
Access
Description
ep_buf2
3
0
R/W
Endpoint Double Buffered Enable
• 0: Endpoint is single buffered.
• 1: Endpoint is double buffered.
USB_EP.ep_int_en
Field
Bits
Default
Access
Description
ep_int_en
4
0
R/W
Endpoint Transfer Complete Interrupt Enable
1: Enable generation of interrupts for this endpoint upon completion of an IN or OUT data transfer.
USB_EP.ep_nak_en
Field
Bits
Default
Access
Description
ep_nak_en
5
0
R/W
Endpoint NAK Interrupt Enable
1: Enable generation of interrupts for this endpoint when a NAK handshake is returned to the host.
USB_EP.ep_dt
Field
Bits
Default
Access
Description
ep_dt
6
0
R/W
Endpoint Data Toggle Clear
Rev.1.3 April 2015