MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.4 Timers/Counters
10.4.4.1.6
TMRn_TERM_CNT16_0
TMRn_TERM_CNT16_0.term_count
Field
Bits
Default
Access
Description
term_count
15:0
0000h
R/W
Terminal Count Setting
In 16-bit timer mode (tmr2x16=1), this register holds the terminal count setting for 16-bit timer 1.
In 32-bit timer mode (tmr2x16=0), this register cannot be accessed and all reads from this location will return zero.
10.4.4.1.7
TMRn_COUNT16_1
TMRn_COUNT16_1.value
Field
Bits
Default
Access
Description
value
15:0
0000h
R/W
Count Value
In 16-bit timer mode (tmr2x16=1), this register holds the current count value for 16-bit timer 0.
In 32-bit timer mode (tmr2x16=0), this register cannot be accessed and all reads from this location will return zero.
10.4.4.1.8
TMRn_TERM_CNT16_1
TMRn_TERM_CNT16_1.term_count
Field
Bits
Default
Access
Description
term_count
15:0
0000h
R/W
Terminal Count Setting
In 16-bit timer mode (tmr2x16=1), this register holds the terminal count setting for 16-bit timer 1.
In 32-bit timer mode (tmr2x16=0), this register cannot be accessed and all reads from this location will return zero.
Rev.1.3 April 2015
Maxim Integrated
Page 605