background image

 

Spangenberg International B.V. 

– Rendementsweg 24P – 3641 SL Mijdrecht – Holland – T. +31 (0) 297 253 969 – F. +31 (0) 297 256 445 

info@spangenberg.nl

 

 

www.spangenberg.nl

 

English

 

 

Introduction 
 

Thank you for purchasing this Maxima product. In order to obtain the maximum benefit and use of this 
product, please read these instructions completely before attempting to install or use this product. 
 
Your new Maxima product was manufactured with advanced production techniques. Every product is 
inspected  and  tested  strictly  to  ensure  safe  and  reliable  operation  before  leaving  the  factory.  All 
parameters have reached or exceeded the national standard. 
 
The Maxima vacuum packing machines can be used  to pack many types  of products. Not only solid 
products as meat or fish, but also liquid products as soup and sauces. These machines are very versatile 
and can be used for many applications. Packing and sealing settings can be changed to your wishes. 
 
At Maxima we are very proud of our products and are completely committed to providing you with the 
best products and service possible. Your satisfaction is our number one priority 
 
We  know  you  will  enjoy  using  this  product  and  Thank  You  for  choosing  our  product.  We  hope  you 
consider Maxima for your future equipment purchases. 
 

The Complete Range vacuum packing machines 
 

Model 

Pump 

Chamber Dimensions 

Dimensions 

Max. Power 

Connection 

MAXIMA MVAC 200 

10 m

3

/h 

H90 x W280 x D385 mm 

H320 x W330 x D480 mm 

370 Watt 

230V/50Hz/1Phase 

MAXIMA MVAC 300 

10 m

3

/h 

H185 x W320 x D370 mm 

H435 x W370 x D480 mm 

370 Watt 

230V/50Hz/1Phase 

MAXIMA MVAC 400 

20 m

3

/h 

H220 x W450 x D460 mm 

H460 x W520 x D560 mm 

900 Watt 

230V/50Hz/1Phase 

MAXIMA MVAC 450 

20 m

3

/h 

H200 x W520 x D540 mm 

H520 x W590 x D680 mm 

900 Watt 

230V/50Hz/1Phase 

MAXIMA MVAC 500 

20 m

3

/h 

H200 x W420 x D440 mm 

H1050 x W475 x D555 mm 

900 Watt 

230V/50Hz/1Phase 

 
Characteristics 

 
This machine  is user  friendly. Working processes of the machine  are: closing the machine cover, air 
exhaustion  (vacuum),  heating,  sealing, cooling,  return-air,  re-opening  of  the  cover.  All  processes  are 
done automatically. 
 
The sealing temperature, sealing time and the vacuuming time can be set with a wide adjustable range, 
this enables the use of various packing bags with different materials and specifications. 
 
This machine is equipped with safe grounding protection and emergency stop button. The emergency 
stop button can be pressed to stop the packing procedure immediately in case of emergency. All Maxima 
machines comply with CE regulations. 
 

Safety Regulations 
 

 

The  machine  may  only  be  used  for  the  purpose  for  which  it  was  intended  and  designed.  The 
manufacturer is not liable for any damage caused by incorrect operation and improper use. 

 

Keep the machine and electrical plug away from water and any other liquids. In the unlikely event 
that  the  machine  should  fall  into  water,  immediately  pull  the  plug  out of  the  socket and  have  the 
machine checked by a certified technician. 

Not following these instructions could give rise to 

life-threatening situations. 

 

Never try to open the casing of the machine yourself.  

 

Do not insert any objects in the casing of the machine. 

 

Do not touch the plug with wet or damp hands. 

 

Regularly check the plug and cord for any damage. When the plug or cord is damaged, you should 
have it repaired by a certified repair company. 

Summary of Contents for MVAC 200

Page 1: ... 31 0 297 253 969 F 31 0 297 256 445 info spangenberg nl www spangenberg nl 1 MAXIMA VACUUM PACKING MACHINES USER MANUAL GEBRUIKERSHANDLEIDING BEFORE USING THIS PRODUCT YOU SHOULD READ THIS USER MANUAL PROPERLY VOOR GEBRUIK DIENT U DEZE GEBRUIKERSHANDLEIDING UITVOERIG TE LEZEN ...

Page 2: ...AXIMA MVAC 400 20 m3 h H220 x W450 x D460 mm H460 x W520 x D560 mm 900 Watt 230V 50Hz 1Phase MAXIMA MVAC 450 20 m3 h H200 x W520 x D540 mm H520 x W590 x D680 mm 900 Watt 230V 50Hz 1Phase MAXIMA MVAC 500 20 m3 h H200 x W420 x D440 mm H1050 x W475 x D555 mm 900 Watt 230V 50Hz 1Phase Characteristics This machine is user friendly Working processes of the machine are closing the machine cover air exhau...

Page 3: ...ound the machine to allow for easy access to the machine and for cleaning and ventilation If your machine is supplied with a factory fitted molded plug then you may plug the unit into a standard electrical outlet Make sure that the voltage of the machine and the wall outlet are compatible If your machine is not supplied with a factory fitted molded plug then a qualified electrical technician must ...

Page 4: ...mp of SEALING lights to enter the sealing time Press the INCREASE or DECREASE key to increase or decrease the sealing time in the range of 0 9 9 seconds First try 1 0 1 5 sec 5 After the sealing time is set press the SET key again the COOLING indicator lamp lights to enter the cooling time in the range of 0 9 9 seconds First try 2 0 3 0 sec 6 After the cooling time is set press the SET key again t...

Page 5: ...angenberg International B V Rendementsweg 24P 3641 SL Mijdrecht Holland T 31 0 297 253 969 F 31 0 297 256 445 info spangenberg nl www spangenberg nl 5 11 ATTENTION DO NOT BLOCK THE AIR HOLE IN THE CHAMBER ...

Page 6: ...in operation After this the process moves to sealing state 8 When the SEALING indicator lights the sealing bar will heat up and the bag will be sealed the panel shows the reverse timing of heating It will enter into cooling state automatically after the reverse timing is finished 9 During the cooling state the COOLING indicator lamp lights According to the time setting the machine does not act whe...

Page 7: ...he Sealer In time the sealer will be worn down simply through usage of the machine The sealing tape on top of the sealer can be replaced as shown below Of course it is also possible to replace the complete sealer which is done in pretty much the same way Release the contactpoints by removing de screws Remove the screws in the bottom and sides of the sealer as shown in the pictures ...

Page 8: ...sides of the sealer and then remove the tape Release the metal strip and remove the strip completely the tools to do this have been delivered with the machine Cut a new heating wire at the right size and replace the old one with it Use the tools to place the heatin wire and lock it in place with the retaining bolt Take at sealing tape a proper length and sticker it on the heating wire ...

Page 9: ...nect the cable of complete sealing bar to the pin then put the sealing bar back to vacuum chamber to finish the installation Cleaning and Maintenance Always remove the plug from the socket before cleaning the machine ATTENTION Never immerse the machine in water or any other liquid Clean the outside and the inside of the machine with a damp cloth water with mild detergent Never use aggressive clean...

Page 10: ...s result from transportation installation improper connections 2 Component damages caused by failing to provide power and voltage as required in technical data 3 Damages caused by disassembling products adjust or change the mechanical and electrical structures without permission 4 Damages caused by improper operation overloading cleaning and maintenance 5 Non man made damage such as damages from a...

Page 11: ...10 m3 h H185 x W320 x D370 mm H435 x W370 x D480 mm 370 Watt 230V 50Hz 1Phase MAXIMA MVAC 400 20 m3 h H220 x W450 x D460 mm H460 x W520 x D560 mm 900 Watt 230V 50Hz 1Phase MAXIMA MVAC 450 20 m3 h H200 x W520 x D540 mm H520 x W590 x D680 mm 900 Watt 230V 50Hz 1Phase MAXIMA MVAC 500 20 m3 h H200 x W420 x D440 mm H1050 x W475 x D555 mm 900 Watt 230V 50Hz 1Phase Kenmerken Deze machine is zeer gebruiks...

Page 12: ...eur of wederverkoper Lees deze gebruikershandleiding volledig voordat u de machine gaat installeren en gebruiken Alle installaties en inwerkstellingen moeten worden verricht door gecertificeerde onderhoudsbedrijven uw wederverkoper of vertegenwoordigers van Maxima De machine moet op een vlak oppervlak worden geplaatst met voldoende ruimte voor ventilatie en reiniging Als uw apparaat is voorzien va...

Page 13: ...n om sealtijd te verhogen of te verlagen in de range van 0 9 9 seconden probeer het eerst tussen 1 0 en 1 5 sec 5 Druk weer op de SET knop en het COOLING lampje gaat branden en u kunt de afkoeltijd instellen Druk op de INCREASE of DECREASE knoppen om afkoeltijd te verhogen of te verlagen in de range van 0 9 9 seconden standaard tussen 2 0 en 3 0 sec 6 Nadat de afkoeltijd is gekozen drukt u op de S...

Page 14: ...EALING lampje brandt wordt de sealbalk verhit de vacuumzak gesloten en voorzien van een seal Hierna zal het apparaat even afkoelen 9 Gedurende dat het COOLING lampje brandt koelt het apparaat af De machine functioneert niet na dit proces wordt er lucht in de kamer gelaten het deksel gaat automatisch open en het verpakkingsproces is afgerond Hierna kunt u beginnen met de volgende cyclus 10 Druk op ...

Page 15: ...pangenberg nl Vervangen van het luchtfilter Vervangen sealstrip Na verloop van tijd kan er slijtage ontstaan aan de sealbalk Deze teflon strip is los te vervangen volgens onderstaand stappenplan Uiteraard is het ook mogelijk om een complete nieuwe sealbalk te plaatsen Maak de contactpunten los doormiddel van de schroefjes te verwijderen ...

Page 16: ... schroefjes uit de sealbalk Volgens de afbeelding Verwijder de kunstsof blokjes aan de zijkant en verwijder vervolgens de teflon sealstrip Maak de stalen sealstrip los en haal deze eruit hiervoor is gereedschap meegeleverd Knip een nieuwe sealstrip op lengte en plaats deze in de sealbalk Plaats de sealdraad met het bijgeleverde gereedschap zo strak mogelijk en draai deze vast met de borgbout ...

Page 17: ...g nl Knip de teflon tape op lengte af en plak deze over de stalen sealstrip Knip de uiteinden in en vouw deze naar binnen zodat de kopse kant afgedicht is Schuif de kunststof blokjes weer op de sealbalk Monteer de sealbalk aan de houder vast Monteer de beide contactpunten doormiddel van de schroefjes en de sealbalk kan weer worden teruggeplaatst ...

Page 18: ...f een andere vloeistof Reinig de machine met een vochtige doek water met mild reinigingsmiddel Gebruik geen agressieve of bijtende middelen Gebruik geen scherpe of puntige objecten Gebruik geen petroleum of andere oplosmiddelen Gebruik een zachte doek met detergent Gebruik geen schurende materialen Verwissel de keerring van de pomp tijdig Zeker wanneer u een lek verwacht of ontdekt Vervang de olie...

Page 19: ...chade veroorzaakt door aansluiting op spanning of voltage niet conform de vereiste specificaties 3 Schade als gevolg van demontage of aanpassingen aan de mechanische of electrische constructie van het apparaat zonder toestemming van de fabrikant 4 Schade als gevolg van overbelasting verkeerd gebruik verkeerde reiniging of slecht onderhoud 5 Niet synthetische schade zoals schade als gevolg van abno...

Reviews: