5-10t Internal Combustion Counterbalance Forklift Truck Operation & Maintenance Manual
-60-
4.4 Failure Removal
Refer to the listed descriptions in Table 4-2.
Table 4-2
Failure
Cause for Failure Generation
Removal Method
Coupling Bolt of Main Reducer
Casing Loosened or Gasket
Damaged
To be tightened or
replaced
Vent Hole Blocked
To be cleaned or replaced
1. Oil Leaked out
from Main
Reducer Casing
Oil Seal Worn out or Damaged
To be replaced
Gear Worn out, Damaged or
Broken
To be replaced
Bearing Worn out, Damaged or
Broken
To be replaced
Gear Clearance Improper
To be adjusted
Fitting between coupling Half
Shaft Gear and Spline of Half Shaft
Loosened
Parts to be replaced
2. Loud Noise
with Speed
Differential
Gear Oil Insufficient
Oil to be added as per
requirement
Summary of Contents for FD100T