43
MAX Arm/Ultra Arm V1
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING
CLOSING
MOTOR 2
MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP
CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E
F
1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14
12
9
7
3
1
14
12
9
7
UL SENSOR 10K
UL SENSOR N.C.
MODE A
MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
dsp board led troubleshooting
DSP Board LED
Problem Condition
Solution(s) for
Problem Condition
Normal
LED
“BATTERY IN ERROR” LED is ON.
“BATTERY IN USE” LED is ON
“BATTERY VOLTAGE (E 1/2 F)” LEDs,
only “E” is ON.
“REPLACE BATTERY” LED is ON.
“BATTERY IN USE” and “POWER”
LED are FLASHING
“UL Entrap” LED is ON
“ERD” LED is FLASHING
“PHOTO CLS” LED is ON
“CLS ONLY 10k” LED is ON
“PHOTO CLS” LED is flashing
“CLS ONLY 10k” LED is flashing
“OPEN ONLY” LED is ON
“OPEN ONLY” LED is FLASHING
“MAX SENSE” LED is ON
“OBD PORT” LED is FLASHING
“PROGRAM” LED is FLASHING
•
“BATTERY Plug” not plugged in to “BATTERY INPUT” port.
•
AC power is lost, operator is in battery back-up mode.
•
Check if Toroid box AC POWER ON/OFF SWITCH is ON.
•
Battery is very LOW. Check if toroid box AC power ON/OFF switch is ON. If so, check AC power.
•
Battery needs to be replaced if BATTERY TEST fails and “REPLACE BATTERY” LED is ON.
•
Battery not plugged in to BATTERY INPUT port.
•
An entrapment event has occurred, check if an entrapment sensor was triggered (see if PHOTO CLS,
OPEN ONLY, or OPEN/CLS LEDs are on).
•
An ERD event may have occurred. Check for gate obstruction.
•
ERD sensitivity is too high for application. Re-adjust ERD setting, (see ).
•
Sensor on PHOTO CLS or CLS ONLY 10k inputs (photocell or edge) may have detected an obstruction
while closing gate.
•
Photocell on PHOTO CLS or CLS ONLY 10k inputs is misaligned with reflector.
•
Sensor on PHOTO CLS or CLS ONLY 10k inputs (photocell or edge) may not be wired properly, (see ).
•
Sensor is NOT a N.C. monitored sensor that is UL 325 2018 compliant.
•
Sensor might need to be re-learned, (see ).
•
Sensor is damaged or malfunctioning.
•
Sensor on OPEN ONLY input (photocell or edge) may have detected an obstruction while cycling gate.
•
Photocell on OPEN ONLY input is misaligned with reflector.
•
Sensor on OPEN ONLY input (photocell or edge) may not be wired properly, (see ).
•
Sensor is NOT a N.C. monitored sensor that is UL 325 2018 compliant.
•
Sensor on OPEN ONLY is damaged or malfunctioning.
•
Sensor might need to be re-learned, (see ).
•
MOST sensitive setting for ERD entrapment detection. Select a less sensitive setting (recommend level
10 thru 16), (see ).
•
Up to 8000 event history and error codes are being downloaded to connected flash drive. Up to 5 min.
•
Program button has been pressed and programming mode is active. Press button again to leave
programming mode.
1
OFF
2
OFF
3
OFF
4
OFF / ON
2 / 5
ON
37
ON
6
OFF
30 / 34
OFF
30 / 34
OFF
29 / 33
OFF
29 / 33
OFF
7
OFF
10
OFF
11
Table continued on next page
11
11
15
15
10
10
ID plug MUST
be plugged in.
12. ID PLUG ERROR
15. EXIT LOOP
14. PRIMARY/SECONDARY
13. SOLAR MODE
5. POWER
7. MAX SENSE
8. MOTOR OVERLOAD
20. CLOSE TIMER
22. ON/OFF BATTERY
23. ANTI-TAILGATE
24. OPEN LEFT
25. OPEN RIGHT
26. GATE OPEN
27. GATE CLOSED
29. OPEN ONLY NC
30. PHOTO CLOSE NC
31. OPEN / CLOSE NC
32. 12VDC OUT
28. MAGLOCK
10. OBD PORT
11. PROGRAM
4. REPLACE BATTERY
3. BATTERY VOLTAGE
2. BATTERY IN USE
1. BATTERY INPUT ERROR
16. CENTER LOOP
17. SAFETY LOOP
18. 12 VDC
19. 24 VDC
33. OPEN ONLY 10K
34. CLOSE ONLY 10K
35. OPEN / CLOSE 10K
36. 12VDC OUT
37. UL ENTRAPMENT
40. CLOSING GATE SPEED
38. GATE TAMPER
39. GATE DISABLE
6. ERD
M
AX
ACTUA
TO
R
AR
M
Summary of Contents for MAX ARM
Page 2: ......