maxon motor control
4-20
Document ID: rel5190
EPOS2 Positioning Controller
Edition: October 2014
EPOS2 24/5 Hardware Reference
© 2014 maxon motor. Subject to change without prior notice.
4.2
Motor Connector (J2)
By default, the controller is set to drive either maxon EC motor (brushless) or maxon DC motor
(brushed) with separated motor/encoder cable. Using a
maxon DC motor with integrated motor/
encoder ribbon cable
, you will need to change the jumpers JP2 and JP3.
Figure 4-8
Motor Connector (J2)
4.2.1
maxon EC motor (brushless)
4.2.2
maxon DC motor with separated Motor/Encoder Cable
Accessories
Cable
Motor Cable (275851)
Notes
Suitable connector
Suitable crimp terminals
Suitable hand crimper
Molex Mini-Fit Jr. 4 poles (39-01-2040)
Molex Mini-Fit Jr. female crimp terminals (44476-xxxx)
Molex hand crimper (63819-0900)
Pin
Signal
Description
1
Motor winding 1
EC motor: Winding 1
2
Motor winding 2
EC motor: Winding 2
3
Motor winding 3
EC motor: Winding 3
4
Motor shield
Cable shield
Pin
Signal
Description
1
Motor (+M)
DC motor: Motor +
2
Motor (-M)
DC motor: Motor -
3
do not connect
4
Motor shield
Cable shield