maxon motor control
EPOS2 Positioning Controller
Document ID: rel5190
4-27
EPOS2 24/5 Hardware Reference
Edition: October 2014
© 2014 maxon motor. Subject to change without prior notice.
4.5.2
Digital Inputs 4, 5 and 6
By default, the digital inputs are defined as follows and may be configured via software.
•
Digital Input 4 “Home Switch”
•
Digital Input 5 “Positive Limit Switch”
•
Digital Input 6 “Negative Limit Switch”
Figure 4-17
DigIN4 Circuit (analogously valid also for DigIN5/6)
For wiring examples
DigIN4 “Home Switch”
DigIN5 “Positive Limit Switch”
DigIN6 “Negative Limit Switch”
D_Gnd
Connector [J5] Pin [5]
Connector [J5] Pin [4]
Connector [J5] Pin [3]
Connector [J5] Pin [1], [2]
Input voltage
0…24 VDC
Max. input voltage
±30 VDC
Logic 0
typically <5.0 V
Logic 1
typically >9.0 V
Input resistance
typically 4 k
Ω
Input current at logic 1
typically 6 mA @ 24 VDC
Switching delay
<50 µs @ 11…24 VDC