65
1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
7.
Remove nut and washer
from unused terminal on
200 amp
circuit breaker
(FIG. 65-1)
. Then, connect
red
(+)
cable to the termi-
nal. Reinstall and tighten
nut.
8.
Remove nut from negative
(-)
battery terminal
(FIG.
65-2)
. Then, connect black
(-)
cable to negative
(-)
battery terminal. Reinstall
and tighten nut.
STEP 11 - CONNECT BATTERIES TO LIFTGATE - Cont’d
RED (+) CABLE
TO PUMP BOX
CHARGE LINE
FROM
VEHICLE BATTERY
BLACK (-) CABLE
TO PUMP BOX
150 AMP
CIRCUIT
BREAKER
NEGATIVE (-)
TERMINAL
BLACK (-)
CABLE
BATTERY
NUT
CONNECTING RED & BLACK CABLES
AND CHARGE LINE
FIG. 65-1
RED (+)
CABLE
200 AMP
CIRCUIT
BREAKER
9.
Remove nut and washer
from unused terminal on
150 amp
circuit breaker
(FIG. 65-1)
. Then, connect
charge line to the terminal.
Reinstall and tighten nut.
Summary of Contents for BMR-CS
Page 103: ......