background image

Low temperature burners  - INDITHERM

®

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON  reserves the right to alter specifications and data without prior notice. 
© 2008 Copyright Maxon Corporation.  All rights reserved.

1 - 2.3 -

13

E - m - 7/08

INDITHERM

®

 with high temperature discharge sleeve - all sizes 

 

[1] Gas inlet is threaded, available in ISO or NPT. 

1)

Gas inlet

2)

Pilot gas connection

3)

Combustion air test connec-
tion

4)

Gas pressure test connec-
tion

5)

90° capacity control crank

6)

Filter housing (optional)

7)

High temperature discharge 
sleeve

8)

Flame supervision port

9)

Spark ignitor

Dimensions in mm unless stated otherwise

burner size gas inlet 

[1]

A

B

C

ØD

E

F

G

H

I

J

K

L

ØM ØN Ø P

S

Weight (kg)

100

1”

365

232 200 257 111 442 100 397 438 224 289 353 320 357

14

12

47

300

1 1/4”

365

231 200 305 111 442

98

397 438 224 289 353 368 405

14

12

57

550

1 1/2”

514

259 200 357 138 541 104 439 466 308 367 400 420 457

14

12

83

700

2”

598

259 200 357 138 786

75

439 504 387 403 448 420 457

14

12

83

850

2”

598

259 200 357 138 777

75

469 502 387 403 448 420 457

14

12

83

1100

2”

597

369 200 408 165 777 140 564 597 387 403 448 471 508

14

12

110

1500

2”

597

369 200 408 165 777 140 564 597 387 403 448 471 508

14

12

110

1800

3”

659

369 200 408 165 809 140 609 667 451 452 480 471 508

14

12

110

1

8

6

5

7

9

4

2

3

Summary of Contents for INDITHERM 100

Page 1: ...be available at burner inlet throughout the entire capacity range 8 Differential pressure to be measured between burner test connection and combustion chamber 9 Flame lengths are derived from measured...

Page 2: ...o alter specifications and data without prior notice 2008 Copyright Maxon Corporation All rights reserved 1 2 3 7 E m 7 08 Materials of construction 1 Housing Cast iron 2 Standard sleeve AISI 310 1 48...

Page 3: ...ilable in ANSI and ISO version Each version will have the main gas inlet connection following either NPT or ISO standards All burners include an adjustable orifice needle valve for pilot flame fine tu...

Page 4: ...ry block for installation in applications where high temperatures can be expected In following cases the use of high temperature version discharge sleeve is required Dimension A is larger than 50mm In...

Page 5: ...und the entire discharge sleeve should be present at all times Piloting and ignition INDITHERM burners have an internal pilot burner Piloting is accomplished by internally bypassing the built in gas b...

Page 6: ...the burner flame Consult MAXON for proper combustion chamber lay out Gas pipe train design The INDITHERM burner is very sensitive to variations in gas pressures at burner gas inlet The burner gas inl...

Page 7: ...e standard 8 Flame supervision port 9 Spark ignitor Dimensions in mm unless stated otherwise burner size gas inlet 1 A B C D E F G H I J K L M N P S Weight kg 100 1 365 225 200 160 111 442 93 390 431...

Page 8: ...8 Flame supervision port 9 Spark ignitor Dimensions in mm unless stated otherwise burner size gas inlet 1 A B C D E F G H I J K L M N P S Weight kg 100 1 365 232 200 257 111 442 100 397 438 224 289 35...

Page 9: ...fice is standard included with the burner and is factory mounted onto the burner pilot gas port In case a burner has been ordered for direct ignition this adjustable orifice is omitted Two available v...

Page 10: ...gnitor can be mounted directly onto the burner spark ignitor connection port To be used on all burner sizes See table below for mounting position C depending on burner size Filter Elements FLT INDI Re...

Page 11: ...nting plate of the burner and the duct wall Optionally available in 2 different types GSK INDI STD to be used in combination with standard discharge sleeves square GSK INDI HT to be used in combinatio...

Page 12: ...have been cured carefully before shipment and shall be kept dry Wetting of the blocks could result in premature failures Handling of INDITHERM burners INDITHERM burners are shipped as complete units...

Page 13: ...t to alter specifications and data without prior notice 2008 Copyright Maxon Corporation All rights reserved 1 2 3 18 E m 7 08 INDITHERM with standard sleeve INDITHERM with block with seal and support...

Page 14: ...reserved 1 2 3 19 E m 7 08 Burner mounting flange Refer to below figure to design a correct burner mounting flange on the installation Mounting flange for INDITHERM burners with standard sleeve Dimen...

Page 15: ...ice 2008 Copyright Maxon Corporation All rights reserved 1 2 3 20 E m 7 08 Mounting flange for INDITHERM burners with high temperature block sleeve Dimensions in mm unless stated otherwise Burner size...

Page 16: ...art up During and after start up check the integrity of the system Check all bolted connections after first firing first time on tempera ture and retighten if necessary Purge For safety reasons it is...

Page 17: ...ded preventative maintenance routine Inspect burner internal parts for wear and oxidation paying special attention to the refractory of the burner block when applicable Inspect associated control inst...

Reviews: