PS-SAU-1900E
Mar. 8
th
,1999 (Rev. 0.0)
--- CONFIDENTIAL AND PROPRIETARY ---
8
Compliance with all or part of the following regulatory standards is optional, but may become
mandatory, dependent upon market requirements..
•
CISSPR22, European Union Standard for Emissions, as a Class B device
•
Russia-specific requirements.
•
India-specific requirements.
•
Canada specific requirements.
Environmental
Operating Temperature (ac power, w/ battery installed):
-15° C to 50° C.
Operating Temperature (battery power):
-15° C to 50° C.
Operating Humidity Range:
0 - 95%, non-condensing.
Storage Temperature (excluding battery):
-40° C to 70° C
.
Storage Temperature (battery):
-40° C to 60° C (t
store
< ½ mo.)
-15° C to 40° C (t
store
< 12 mo.)
5° C to 25° C (t
store
> 12 mo.)
Features and Functions
RF Interface Definition:
Per J-STD-008, Mobile Station - Base Station
Compatibility Standard for 1.8 to 2.0GHz Code
Division Multiple Access Personal Communications
System
Vocoder Requirements:
8 kbps CELP and 13 kbps QCELP, EVRC as optional.
Vertical Network Feature Support:
C
ALL
W
AITING
C
ANCEL
C
ALL
W
AITING
C
ALL
F
ORWARD
C
ANCEL
C
ALL
F
ORWARD
C
ONFERENCE
C
ALLING
C
ALL
T
RANSFER
C
ALLER
ID N
UMBER
D
ELIVERY
(US B
ELLCORE
C
OMPLIANT
)
C
ALLER
ID N
AME
D
ELIVERY
(US B
ELLCORE COMPLIANT
)
L
INE
R
EVERSAL
.
Data Services:
IS-99, IS-707
Plug-in Analog Fax Module(MDL-1, optional)
(9600BPS G3 Fax only)
Programming Interface:
Programming supported via a special isolated
interface adapter, which will be supplied only to
installation personnel. A PC-based software package
and an RS-232 interface converter will facilitate
product configuration and test capabilities.
Telephone Network Emulation:
Product provides emulation of “short loop” loop-start
analog telephone interface, including signaling, talk,