Upon receipt of your Maxon RadMax™ Burner, it may
be necessary to install the burner heads to the burner
manifold. The burner heads are shipped completely
assembled and only require two fasteners per head to
attach them to the burner manifold.
Assembly Instructions
Following the illustrations below, mount the burner head
to the manifold:
1. Place the gasket on the air/gas inlet on the under-
side of the burner head. This gasket is used to help
provide a gas tight seal and must be installed.
2. Place the head on the manifold such that the plug
mates up with the hole in the manifold.
3. Use two M8 screws and two M8 washers (provided)
to attach the bottom clamp against the manifold and
securely fasten the head. Alternate the tightening of
the bolts to ensure an even clamping force.
4. Repeat for the remainder of the burner heads. Make
sure the “face” or tile sides of the heads are rela-
tively flush with each other before final tightening of
the fasteners to 3-5 foot-lbs.
Gasket
Detail of Gasket Installation