PATENTS PENDING
8
11921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
LIFT FOOTPRINT ON VEHICLE FLOOR
(LIFT WITH 33” OR 34” PLATFORM)
FIG. 8-2
42.5”
15”
The WL7 Lift must be bolted to the vehicle
body. Body must withstand the maximum
vertical force (“
F
”) and moment of force (“
M
”)
(FIG. 8-1 and TABLE 8-1 )
produced
by the Lift on the vehicle
fl
oor surface shown
in
FIGS. 8-2 and 8-3
.
VEHICLE REQUIREMENTS
Consult body manufacturer for body
strength data. Make sure the forces
created by the Lift are within the limits
prescribed by body manufacturer.
BODY STRENGTH
The minimum vehicle requirements
for installing the WL7 Wheelchair Lift
are described below. Installing the
Lift in accordance with the vehicle
requirements and the instructions in
this manual will result in an installation
that is compliant with Federal Motor
Vehicle Safety Standard (FMVSS) 403
and FMVSS 404.
WARNING
!
FORCE & MOMENT PRODUCED
BY LIFT ON VEHICLE FLOOR
FIG. 8-1
LIFT FOOTPRINT ON VEHICLE
FLOOR (LIFT WITH 30” PLATFORM)
FIG. 8-3
39.5”
15”
M
F
NOTE:
The Lift represents approximately
400 lbs. of “F” shown in the illus-
tration.
MODEL
“F” (LB) “M” (LB-IN)
WL7-vers. C
2800
154,000
WL7-vers. C-1K 3400
187,000
TABLE 8-1
Summary of Contents for WL7-vers. C