Timer
TH5C
Operation Manual
1
Panel Function
Upper display (PV)
Displaying counting value or
parameter
Below display (SV)
Displaying setting value or parameter
Shift key
Moving digit or switching display
( pushing it for 3 sec to enter set
mode )
Decreasing key
Increasing key
Rst
Reset key
Use for resetting or entering SV
LED
Run
:
flickering when counting
Out
:
lighting when output “on”
K/P
:
lighting when key locked
Reset
:
lighting when reset operation
Start
:
lighting when starting
Gate
:
lighting when stopping
H
:
lighting when hour selected
M
:
lighting when minute selected
S
:
lighting when second selected
Run
Out
K / P
Rst
SET
Rst
Start
Gate
H
M
S
TH5C
2
Set Time Method
Setting time can be changed during counting or stop counting.
Pushing 1 sec for LED flickering then push or
to increase or decrease the set time.
Rst
Pushing to move digit position, it is cycle .
It must push key to enter the SV after setting.
3
Parameter Flow Chart & Function
Setting value can be changed during counting or stop counting
Pushing key for 3 sec then use & key to select the mode.
Push 3 sec
Returning to initial
display after 20 sec
no operation.
Time ranges
Time range selection
9.999sec
9999min
99.99sec
999.9hr
999.9sec
9999hr
9999sec
99min59sec
999.9min
99hr59min
S
S
M
S
…….
H
M
Use setting time range.
Select time range
Up / Down counting
Output mode
Output time
Input time
Key lock mode
Output contactor
Return 1tE (time range)
Use setting up / down counting.
Up Down
Use setting output mode.
Select time operation
* Refer to output mode diagram. TH5C without A1, A2, A3, B1, B2, C, D, F
A
A1
A2 A3 b b1 b2 C d E F
Use setting time range.
* Output mode C, D, E, F without this function
Hold 0.1S 0.5S 1S 5S 10S 15S 20S
Use setting time range.
* 1ms=1/1000sec * TH5C-8 without this function
1ms 20ms
ALL UNLOCK RESET ADJ SET
Use setting lock mode.
* Push + for 3 sec to perform lock or release lock
Use setting the output contactor.
* TH5C-8S and TH5C-11S without this function
2C 1A1C
http://www.maxthermo.com
4
Timing Charts
Either one-shot output or sustained output can be selected
Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts
when the power comes ON or when the
reset input goes OFF.
The control output is controlled using a
sustained or one-shot time period.
Timing starts when the start signal goes ON.
and is reset when the start signal goes OFF
While the start signal is ON, the timer starts
when the power comes ON or when the
reset input goes OFF.
The control output is controlled using a
sustained or one-shot time period.
Mode A :
Signal ON Delay
(Timer resets when
power comes on)
Mode A1 :
Signal ON Delay2
(Timer resets when
power comes on or
when START signal
goes off)