background image

 

 

File this owner’s manual in a safe place for future reference. 

It contains operating procedures – maintenance procedures – 

trouble shooting guide – replacement parts guide – order form – and contact information. 

You will need this! 

Maxx Air Portable Evaporative Cooler 

 

1.0

 

Introduction 

 

Your Maxx Air was tested 3 ways. Your unit was 

tested for

 1. Maximum air flow at operating static pressure.  

Only Maxx Air is 

tested in operating conditions

 with 2. 

Water

 and 3. 

Electricity

 before it is shipped.  

 

Maxx Air is 

easy to operate

 – needs only tap water and electricity to operate. 

 

Maxx Air is 

easy to move

 – roll your Maxx Air to the area you 

want to cool. Maxx Air comes standard with straight and swivel 

/ lock casters which make moving your Maxx Air a breeze. 

 

1.1 

Quick Start

 – Your Quick Start Information is located inside the 

information packet shipped with your unit.  

Look on the front of your Maxx Air in a plastic sleeve. 

 

1.2 Evap-O-Matic – Chemical Water Treatment. Operate your unit 2 

weeks – flush out old water – add clean water – then add Chemical Water 

Treatment tablet. Note; Tablet makes water foam which can cause unit to 

spit droplets of water temporarily. Foam subsides in 1 – 2 working days. 

You can order more tablets by calling 1.800.433.1626 

 

2.0  How Evaporative Cooling Works 

Keeping in mind that regular fans only circulate same temperature air - same humidity – your Maxx Air portable evaporative 

cooler  takes  that  same  existing  air,  combines  it  with  evaporating  water 

(which  dramatically  lowers  the  temperature

immediately relieving hot, dry areas, similar to the conditions when a natural rain storm approaches, the temperature drops 

noticeably  cooler,  because  the  air  is  saturated  with  water.  Because  your  air  is  now  saturated  with  water  it  becomes 

noticeably  cooler.  In  high  humidity  areas  the  temperature  will  not  be  as  cool  –  however,  the  Maxx  Air  was  engineered 

efficient

 to evaporate perspiration and sweat from employees to keep them cooler. 

 

3.0  Unpacking your new Maxx Air unit 

Note: Carefully examine your Maxx Air shipping carton for damage before  

opening. If your carton is damaged – notify the shipper immediately! 

Your EC36D1 unit was shipped on a wooden skid covered with a cardboard cover  

and lid – strapped. First remove the straps then you may lift the whole cardboard  

box off the unit and skid. Your Maxx Air must now be lifted off the wooden skid. 

 

4.0  Set-up your Maxx Air unit.  

Roll your Maxx Air unit to a level surface and lock the swivel casters to prevent  

accidental movement.  

 

 

 

Electrical cord for 120V, 20Amp connection. 
Note: Standard 

¾” 

water connection for 

utility water source under 60 p.s.i. 
 

How the Maxx Air portable 

evaporative cooler works 

Summary of Contents for EC36D1

Page 1: ...ile this owner s manual in a safe place for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information Y...

Page 2: ...rcuit is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate se...

Page 3: ...supply 4 2 Connecting the water supply 5 0 Operating procedures 5 1 Filling the units reservoir with water 5 2 Turn on pump 5 3 Adjust water flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Tur...

Page 4: ...433 1626 2 0 How Evaporative Cooling Works Keeping in mind that regular fans only circulate same temperature air same humidity your Maxx Air portable evaporative cooler takes that same existing air co...

Page 5: ...1 Filling the units reservoir with water Once your water hose is connected open the water flow valve located on the front of your unit only one and quarter 1 1 4 turns This water flow valve adjusts th...

Page 6: ...n fan to low let cooling pads get saturated then turn fan on high for cooling Adjust the water flow Your Maxx Air operates most efficiently and maintains uniform cooling pad wetness with the water con...

Page 7: ...ce 15 minutes before quitting time turn off the water pump and let the fan run 10 15 minutes to dry out the cooling pads before leaving Inspect the cooling pads to make sure they are thoroughly dry th...

Page 8: ...xx Air units usually operate at peak performance at 1 turns Repair as necessary Reduce the water flow with the water control valve located on the front of the unit Search for leaks and repair as neces...

Page 9: ...p Flush water from unit s water reservoir more frequently See section 7 4 8 0 Storage Remove pads as described above in 7 2 and rinse pads clean with fresh water Dry cooling pads in sunlight Drain wat...

Page 10: ...reserves the right to demand and receive written evidence of the date of purchase before undertaking its obligations under this warranty The right to demand and receive written evidence of date of pur...