background image

 

 

using a 7/16” wrench – remove the two retaining bolts from the backside and topside (cooling pad side) of the unit. These 

two bolts hold the metal angle retaining bar and the  cooling pads in place. Next, remove the angle retaining bar and set to 

side. Now you are ready to remove your unit’s cooling pads. 

 

7.2  Removing the cooling pads 

Before your start, make a note of the direction of the angle of the pads flutes (see side 

of pads). You must put pads back in correct order for your unit to function  

effectively. (Note: Install steep side 45° angle flute to the back of unit.) 

Once the retaining angle bar is removed from the top of your Maxx Air unit, reach to the  

top of the dry cooling pad to the left and gently take hold of the top of the pad and gently  

pull back and slightly down – this action will loosen the pad from the unit. Look at the  

direction of the angle of the pad flutes 

(side of pads

). Remove the cooling pad and proceed  

to the next pad. Then, remove all five cooling pads and gently set in a safe place.  

Note: this is a good time to take the cooling pads outside and run clean water over the pads to remove any accumulated dirt  

and debris. 

Do not use high pressure hose

 – this will damage pads and their ability to function effectively. Make sure the  

pads are thoroughly dry before placing back inside the unit. Full exposure to the sunlight is a good way to dry the pads  

while helping remove mold and mildew. 

 

7.3  Daily maintenance 

15 minutes before quitting time – turn off the water pump and let the fan run 10 – 15 minutes – to dry out the cooling pads 

before leaving. Inspect the cooling pads to make sure they are thoroughly dry (this action helps to reduce mold and mildew) 

when pads are completely dry then turn-off fan. 

 

7.4  Periodic maintenance 

Depending upon your environment and how often you operate your Maxx Air will depend on how dirty your water gets in 

the reservoir and how often you will need to clean it. If you begin to detect an algae smell coming from your unit  – it’s time 

to  flush  your  Maxx  Air  reservoir  with  fresh  water.  Refer  to  and  follow  the  steps  above  in  7.2  and  you  will  only  need  to 

remove 1 or 2 of the cooling pads from the left side of the unit to gain access to your water reservoir. Take a small sponge 

and clean out your water reservoir with a light cleaner and wipe it down completely and let the unit dry. (You may want to 

use a wet / dry shop vacuum to clean out unit). When unit is clean add an Evap-O-Matic tablet – then replace your cooling 

pads (make sure flutes are facing correct direction) retaining bar and bolts and add fresh, clean water back to the units’ water 

reservoir.  Note:  Adding  Evap-O-Matic  helps  to  reduce  algae,  mold  and  mildew.  You  can  order  more  tablets  by  calling 

1.800.433.1626.   

Note: You may want to remove most of water from water reservoir by attaching a garden hose to the drain valve  and place 

the end of the garden hose into a drain then, running pump until sump is dry – shutting off pump immediately.  

Warning! Do not run pump without water in the reservoir.

 This action will burn up your Maxx Air’s water pump. 

 

 

 

 

 

Summary of Contents for EC36D1

Page 1: ...ile this owner s manual in a safe place for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information Y...

Page 2: ...rcuit is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate se...

Page 3: ...supply 4 2 Connecting the water supply 5 0 Operating procedures 5 1 Filling the units reservoir with water 5 2 Turn on pump 5 3 Adjust water flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Tur...

Page 4: ...433 1626 2 0 How Evaporative Cooling Works Keeping in mind that regular fans only circulate same temperature air same humidity your Maxx Air portable evaporative cooler takes that same existing air co...

Page 5: ...1 Filling the units reservoir with water Once your water hose is connected open the water flow valve located on the front of your unit only one and quarter 1 1 4 turns This water flow valve adjusts th...

Page 6: ...n fan to low let cooling pads get saturated then turn fan on high for cooling Adjust the water flow Your Maxx Air operates most efficiently and maintains uniform cooling pad wetness with the water con...

Page 7: ...ce 15 minutes before quitting time turn off the water pump and let the fan run 10 15 minutes to dry out the cooling pads before leaving Inspect the cooling pads to make sure they are thoroughly dry th...

Page 8: ...xx Air units usually operate at peak performance at 1 turns Repair as necessary Reduce the water flow with the water control valve located on the front of the unit Search for leaks and repair as neces...

Page 9: ...p Flush water from unit s water reservoir more frequently See section 7 4 8 0 Storage Remove pads as described above in 7 2 and rinse pads clean with fresh water Dry cooling pads in sunlight Drain wat...

Page 10: ...reserves the right to demand and receive written evidence of the date of purchase before undertaking its obligations under this warranty The right to demand and receive written evidence of date of pur...

Reviews: