then, you are ready to turn on fan and begin to feel the cooling effect from your new Maxx Air. Note: After your cooling 

pads are broken in (typically takes 1 -2 weeks in operation) it will take less time to saturate pads for start-up.  

 
5.4  Turn-on Fan 

Once your cooling pads are wet – you may turn on your Maxx Air unit. Now you can begin to feel the Maxx Air difference 

in temperature. After your Maxx Air has run for 5 minutes or so, visually inspect the pads – if water is dripping outside the 

unit – you have too much water, simply turn the  water flow valve to the right ½ turn and inspect water flow in another 5 

minutes. If there are dry streaks in the cel deck pads open the water flow valve handle ½ turn to increase water – check water 

flow  in  another  5  minutes  and  adjust  accordingly.  Most  Maxx  Air  operations  work  effectively  with  valve  opened  at  1  ¼ 

turns. This water valve is efficient – it requires minimal turning. 

 

6.0  

Daily Operating procedures

 

 

6.1  Turn-on water supply to Maxx Air unit. Then, turn on water pump. 

Turn on water pump to unit – then, turn on fan to low – let cooling pads get saturated – then turn fan on high for cooling. 

Adjust  the  water  flow  –  Your  Maxx  Air  operates  most  efficiently  –  and  maintains  uniform  cooling  pad  wetness  with  the 

water control valve turned on at 1 ¼ turns. You must determine what works best for you and your specific environment. 

 

6.2  Adjust water flow 

Your Maxx Air operates most efficiently – and maintains uniform cooling pad wetness with the water control valve turned 

on at 1 ¼ turns. You must determine what works best for you and your specific environment. 

 

6.2  Turn on fan 

When you can see that the cooling pads are saturated with water – turn fan on high and feel the cooler air coming from your  

Maxx Air unit. Adjust the fan speed for your comfort. 

 

6.4  Turn-off Maxx Air unit at end of day.  

15 minutes before closing for the day – turn off water pump with toggle switch – leave fan running – this action will shut-off 

water to the cooling pads while keeping the fan running. The fan will dry out the  cooling pads. When the cooling pads are 

thoroughly dry – turn off fan. Drying your cooling pads thoroughly - everyday will help prevent mold and mildew growth, 

plus it will prolong the life of your cooling pads. 

Turn off water supply to unit.

 

 

7.0  Maintenance 

  

7.1  Access inside of unit 

Turn-off water pump and let the fan continue to run until the cooling pads are thoroughly dry (about 10 – 15 minutes). Once 

your cooling pads are completely dry you may turn-off fan. Now unplug electricity to unit to avoid unnecessary shock. Next, 

using a 7/16” wrench – remove the two retaining bolts from the backside and topside (cooling pad side) of the unit. These 

two bolts hold the metal angle retaining bar and the  cooling pads in place. Next, remove the angle retaining bar and set to 

side. Now you are ready to remove your unit’s cooling pads. 

Summary of Contents for EC48B2

Page 1: ...File this owner s manual in a safe place for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information...

Page 2: ...rcuit is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate se...

Page 3: ...2 Turn on pump 5 3 Adjust water flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Turn on pump 6 2 Adjust water flow 6 3 Turn on fan 6 4 Turn off unit 7 0 Maintenance 7 1 Access inside of unit 7...

Page 4: ...ir same humidity your Maxx Air portable evaporative cooler takes that same existing air combines it with evaporating water which dramatically lowers the temperature immediately relieving hot dry areas...

Page 5: ...u need to cool 5 1 Filling the units reservoir with water Once your water hose is connected open the water flow valve located on the front of your unit only one and quarter 1 1 4 turns This water flow...

Page 6: ...you and your specific environment 6 2 Adjust water flow Your Maxx Air operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned on at 1 turns You must de...

Page 7: ...maintenance Depending upon your environment and how often you operate your Maxx Air will depend on how dirty your water gets in the reservoir and how often you will need to clean it If you begin to de...

Page 8: ...air as necessary Push bottom of cooling pads gently inside to stop leaking Check you pressure Max water pressure is 413 KPA 60 p s i adjust water supply valve to 1 turns or install a water pressure re...

Page 9: ...n sunlight Drain water reservoir completely and wipe dry Replace dry cooling pads Replace top angle bar to hold pads in place Store Maxx Air in dry clean area and cover to prevent dust build up to hav...

Page 10: ...reserves the right to demand and receive written evidence of the date of purchase before undertaking its obligations under this warranty The right to demand and receive written evidence of date of pur...

Reviews: