OPERATION OF YOUR

 

MAXXFAN Dome fan 

 

To open the MAXXFAN Dome lid push the button on the handle to dis-engage the clip and 
slide the handle away from you until the clip engages the upper opening. 

 

To close the lid, push the button on the handle to dis-engage the clip and pull the handle 
toward you until the clip engages the lower opening. 

 

Operation of your 

MAXXFAN Dome 

simply entails pushing the ON/OFF button on the fan to 

activate the exhaust fan. 

 

The optional LED lighting on the garnish ring is operated by the push button on the garnish 
ring. The LED lighting and fan operate independently  

 

Close the lid to impede infiltration of air when exhaust fan is not in use.  

 

The MAXXFAN Dome fan should not be operated with the lid closed. 

USER INSTRUCTIONS SERVICING  

Cleaning of your 

MAXXFAN Dome 

may be achieved with mild soap and water only. The screen 

can be removed for cleaning by removing the four (4) screws. 
Before removing the screen for cleaning, ensure the fan is turned to the OFF position. 

CAUTION: Do not operate the fan with the screen removed. 

The

 MAXXFAN Dome 

fan has a 5 amp fuse. To access the fuse, turn the fuse cap to the left to 

remove the cap. Replace the fuse with a 5 amp, type GMA fast acting fuse. Replace the fuse cap to 
secure the fuse in the fuse holder. 

Should you have questions, please contact AIRXCEL / MAXXAIR VENTILATION SOLUTIONS 
Customer Service at 316.832.4357. 

For WARRANTY information, please visit www.airxcel.com/maxxair. 
 

Summary of Contents for MAXXFAN DOME 3810

Page 1: ... accommodate the additional load Circuit must be fused and use appropriate gauge stranded wire for electrical connections WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit in the manner intended by AIRXCEL INC If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the s...

Page 2: ...This page intentionally left blank ...

Page 3: ... the MAXXFAN Dome fan into the roof opening orient the fan with the button toward the front of the coach ensure that the fan wires are hanging to the inside of the coach Center the fan in the opening Using the eight 8 screws provided attach the flange to the roof at each dimple location along the flange Note Opening the fan lid gives better access to the flange for assembling the screws Screw into...

Page 4: ...FAN Dome fan has been installed remove the excess BUTYL caulk that may have squeezed out Use silicone to apply a daub over every exposed screw head In addition apply a bead of silicone approximately 3 16 dia along the outside edge of the flange all the way around the fan STEP 4A Center the Rain Shield over the fan with the slots facing downward as shown Using six 6 screws provided attach the rain ...

Page 5: ...ICKNESS LENGTH TO ADD TO CEILING WALL THICKNESS MEASUREMENT LED NON LED 1 1 8 to 5 7 8 inch 15 16 inch 1 2 inch STEP 6 Non LED MAXXFAN Dome Using the supplied wire splices connect the Positive 12VDC supply wire to the MAXXFAN Dome fan wire marked POS 12VDC and the Negative 12VDC supply wire to the MAXXFAN Dome fan wire marked Neg 12VDC If the sleeve is needed insert the sleeve into the garnish rin...

Page 6: ...fan wire and the LED light wire marked Neg 12VDC If the sleeve is needed insert the sleeve into the garnish ring positioning the notch in the sleeve to line up the wiring Raise the garnish ring to the ceiling wall ensuring that the garnish ring is centered over the fan opening If using the sleeve the sleeve will overlap the base that extends in the opening This will help center the garnish ring in...

Page 7: ...iltration of air when exhaust fan is not in use The MAXXFAN Dome fan should not be operated with the lid closed USER INSTRUCTIONS SERVICING Cleaning of your MAXXFAN Dome may be achieved with mild soap and water only The screen can be removed for cleaning by removing the four 4 screws Before removing the screen for cleaning ensure the fan is turned to the OFF position CAUTION Do not operate the fan...

Page 8: ...PLACE CONSUMER LABEL HERE For additional product information please visit www AIRXCEL com AIRCEL INC RV Products Division MAXXAIR 3050 N St Francis St Wichita KS 67219 316 832 3400 ...

Reviews: