KEYPAD CONTROLS
FOR
MAXXFAN
®
Plus
MODELS
4000KI • 4500KI • 4540KI
NOTE: A beeping sound will
confirm each key press
ON/OFF:
Use this key to
start the fan or to turn off the fan.
On Automatic Opening Models, the
lid will also open or close when the
fan is turned on or off. On Manual Opening Models, pushing this key while in Auto Mode
will exit Auto Mode, turn off the fan and the lid will stay in the position you selected. On
Automatic Opening Models, this button will exit Auto mode, turn the fan off, and close the
lid.
IN/OUT:
Use this key to reverse the direction of the fan, the fan will slow down and
pause for two (2) seconds before resuming operation in the opposite direction.
Note:
In
Auto Mode the fan direction is automatically positioned to Exhaust, but may be overridden
and changed to Intake by depressing this key.
Note:
Some models are Exhaust Only. On
these models this key is deleted.
AUTO:
Auto Mode allows the thermostat to turn the fan
ON and OFF
depending on
the thermostat setting. Press this key once for less than three (3) seconds to enter Auto
Mode, three (3) quick beeps will confirm the MAXXFAN has entered Auto Mode. To EXIT
Auto Mode, press the
ON/OFF
key. Initial factory set point for the thermostat is 26°C.
The green LED will light to indicate the MAXXFAN is in Auto Mode. To adjust, follow
instructions below:
If no previous thermostat temperature was entered, or you wish to change a previous set
temperature, press the HOLD TO SET key for more than 3 seconds and you will hear one
long beep and the thermostat will be reset to 26°C. To further adjust the set temperature,
if desired, use the (+) or (-) Arrow keys to adjust at 0.5°C per press. The fan will emit a
beeping sound to confirm this setting. If a previous thermostat temperature was entered,
the fan will remember this temperature setting and the next time you enter Auto Mode, the
fan will start ventilating automatically as directed by the thermostat. The fan speed will
automatically adjust based on the cabin temperature. As cabin temperature rises, the fan
increases in speed.
Note:
If 12 volt Caravan power is removed from the MAXXFAN, the
thermostat will be reset to 26°C.
ARROW
When in Auto Mode:
Use the (+) & (-) Arrow keys to adjust the thermostat set temperature
up or down by 0.5°C per press.
When in Manual Mode:
Use the (+) & (-) Arrow keys to adjust the fan speed up or down.
When the fan speed reaches either the maximum or minimum speed, the fan will respond
with 2 quick beeps to indicate this.
ARROW KEYS PRESSED TOGETHER:
Automatic Lift Models Only
Press the (+) & (-) Arrow keys at the same time to Open or Close the lid. The fan motor
will remain in its current state.
RAIN SENSOR:
4500/
4540 Models Only
Press this key to turn the Rain Sensor OFF. This will deactivate the Rain Sensor. The
red LED will light to indicate that the Rain Sensor is deactivated. Use caution when
deactivating the Rain Sensor as rain could enter your Caravan. If the Rain Sensor circuit
detects rain, it will turn off the fan and close the lid. The red LED will blink to indicate that
the Rain Sensor has shut the fan off. Press the Rain Sensor key again to reset the fan
and extinguish the blinking LED.
Note:
CAUTION: the Rain Sensor will not close the
MAXXFAN lid if the lid is opened manually with the knob.
HOLD
TO SET