Installation - Existing Construction (continued)
8
Install the grille
□
Pinch the mounting springs on the grille (8) and insert them
into the narrow rectangular slots inside the fan. Push the grille
(8) up toward the ceiling.
□ Turn on electricity at the breaker box after finishing installation.
Care and Maintenance
.A
WARNING: Disconnect power supply before servicing.
□ See SAFETY INFORMATION before proceeding. Routine maintenance should be done at least once a year.
□ Never use solvents, thinner or harsh chemicals for cleaning the fan.
□
Do not allow water to enter the motor.
0
Do not immerse metal parts in water.
Troubleshooting
Problem
Possible Cause
The CFM is too great.
The damper is damaged or not working properly.
The fan seems louder than
it should.
The bend in the duct is too close to the fan discharge.
The fan discharge is reduced to fit a smaller duct.
The fan body is not attached securely.
There is insufficient airflow intake in the room.
There is insufficient CFM.
The fan is not clearing the
room.
Solution
Be sure the CFM rating on the fan matches the square
footage of your room.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please call
Customer Service.
Be sure you do not have any sharp bends in the duct closer
than 18 in. to the fan discharge.
Use the recommended size ducting to reduce fan noise.
Be sure the fan is securely attached to the ceiling joists.
Be sure a door or window is slightly ajar or opened to allow
airflow. The fan is not able to draw air out of the room without
enough airflow to draw from.
Be sure the CFM rating on the fan matches the requirements
for your room size.
NOTE: Using a tissue is not the correct method for
�
determining if the fan is operating properly. If the fan
clears steam from the room within approximately 15
minutes of completeing your shower, then the fan is
operating properly.