2202G1JE-DA-M-N_2010.01.
5 Maintenance
Reciprocating Compressor M Series
5.5 Disassembly/Assembly
5-21
5.5.3.6 Attentions for Attaching the Head Jacket Cover
Dropping of the head jacket cover may cause injury or damage to the
compressor. Always attach the stud bolts before performing the work.
1.
After attaching the stud bolt (a) into the head
jacket cover hexagon head screw hole for one
section at the top, attach the head jacket cover.
2.
After temporarily tightening the rest of the head
jacket cover hexagon head screws, remove the
stud bolt.