WARNING 

It is recommended that charging should be supervised  at all times. Monitor the temperature of the battery 
during charging. If the temperature of the battery exceeds 40

0

C cease charging until the battery has cooled to 

a safe temperature. Failure to do so may result in the battery exploding.   

 

3.  WHEN  CHARGING IS COMPLETE 

The “CHARGED” LED indicator will illuminate and the charger will continue to monitor & maintain the battery. 

 
4.  DISCONNECTING THE CHARGER 

Switch off the mains supply, unplug the charger from the mains (To reduce risk of damage to the mains cable, 
pull by the plug rather than cable) & disconnect the clips from the battery, negative lead (BLACK) first. Then 
disconnect the positive lead (RED) from the battery.  

 

For non-sealed lead-acid batteries: Inspect the liquid levels in each cell and top up if necessary, using the 
correct fluid.  Now push home or tighten the caps.  Any surplus fluid around the cell tops should be wiped off 
(this should be done with extreme care as it is acidic).  If the battery has been removed for charging, replace 
it and re-co

nnect the cables according to the manufacturer’s instructions. 

 

Charging Curve 6 Volt 

 

Charging Curve 12 Volt 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MP7403

Page 1: ...dangerous and electrical repairs or replacement of the mains cable should only be carried out by the manufacturer its service agent or a suitably qualified electrician electrical technician in order to avoid a hazard Resultant damage to the product will result in the loss of your guarantee GENERAL SAFETY This appliance is not intended for use by persons including children with reduced physical sen...

Page 2: ...of an authorised place for the recycling of electrical and electronic appliances must be sought Contact your local authority for information concerning local Household Recycling Centres with applicable facilities This product must not be disposed of with general domestic waste SCOPE OF USE This product is only to be used for charging 6V or 12V lead acid sealed lead acid maintenance free and AGM ve...

Page 3: ...ill installed Connect the negative charging lead BLACK to the vehicle chassis well away from the battery fuel line and hot or moving parts For batteries removed from the vehicle Connect the negative charging lead BLACK to the negative post of the battery marked ve or N After connecting the clips rotate them slightly to remove any dirt or oxidization thus ensuring a good contact 2 CHARGING WARNING ...

Page 4: ...supply unplug the charger from the mains To reduce risk of damage to the mains cable pull by the plug rather than cable disconnect the clips from the battery negative lead BLACK first Then disconnect the positive lead RED from the battery For non sealed lead acid batteries Inspect the liquid levels in each cell and top up if necessary using the correct fluid Now push home or tighten the caps Any s...

Page 5: ...charging Or falls below 6V within 2mins after fully charged Then battery will be determined as bad battery and ERROR LED will be illuminated Have the battery tested by a qualified technician Replace the bad battery if necessary Charging a 12V battery If the voltage does not reach 11V 0 2 after 4 mins charging Or falls below 12V within 2mins after fully charged Then battery will be determined as ba...

Page 6: ...equires minimal maintenance As with any appliance or tool a few common sense rules will prolong the life of this battery charger ALWAYS BE SURE THE CHARGER IS UNPLUGGED BEFORE PERFORMING ANY MAINTENANCE OR CLEANING 1 Store in a clean dry place to avoid moisture damage 2 Loosely coil up the cords when not in use 3 Clean the case and cords with a slightly damp cloth 4 Clean any corrosion from the cl...