background image

 

MP7950 12V Automatic Digital Air Compressor

 

www.maypole.ltd.uk 

 
 
 
 
 

Your analogue compressor is designed to be used from the standard 12V dc socket in most vehicles, to inflate car and bike 
tyres, balls, etc. This product is intended for household, consumer use only. 

 
 

 

● 

Read all safety warnings and all instructions.

 

Save all warnings and instructions for future reference.  

Work area safety 

● 

Keep work area clean and well lit. Cluttered or dark areas 

invite accidents. 

● 

Do not operate compressor in explosive atmospheres, such 

as in the presence of flammable liquids, gases or dust. Power 
tools create sparks which may ignite the dust or fumes. 

● 

Keep children and bystanders away while operating the 

compressor. Distractions can cause you to lose control. 

The plug must match the outlet. Never modify the plug in 

any way.  

● 

Do not expose the compressor to rain or wet conditions. 

Water entering the compressor will increase the risk of 
damage. 

● 

Do not use if the switch (1) does not turn the compressor 

on and off.  

● 

Disconnect the plug from the power source tool before 

making any adjustments, changing accessories, or storing 
power tools.  Such preventive safety measures reduce the risk 
of starting the power tool accidentally. 

● 

Store compressor out of the reach of children and do not 

allow persons unfamiliar with the compressor or these 
instructions to operate the compressor.  

● 

Always check the compressor before use. If damaged, or 

worn, do not use. 

 

Device-specific safety instructions 

● This appliance may not be used by children or people with 

reduced physical, sensory or mental capabilities or a lack of 
experience and knowledge. Children must not use the 
appliance as a plaything. Cleaning and user maintenance tasks 
may not be carried out by children unless they are supervised. 

● Avoid using the compressor at temperatures below +5 

degrees. 

● Never leave the compressor unsupervised while it is in use.

 

● Ensure that the ON/O

FF switch is turned off when 

connecting to the power supply. 

● Caution! Operate the compressor only for a short time. The

 

appliance may overheat if operated continuously for longer 
than 10 minutes. Switch the appliance off immediately and 
allow it to cool down for at least 10 minutes.  

 

● 

Risk of injury!

 Do not inflate any objects to more 

than the intended pressure. They could burst and 
cause injury and/or material damage. 

● Do not exceed the permissible output range of the 

compressor. Do not pump up any lorry, tractor or 
other large tyres. 

● Never use the appliance for purposes other than the 

ones for which it was designed. 

● The appliance must always be kept clean, dry and 

free from oil or grease. 

● 

Stay alert, watch what you are doing and use 

common sense when operating a power tool. Do not 
use a power tool while you are tired or under the 
influence of drugs, alcohol or medication.  

● 

Use personal protective equipment. The use of 

personal protective equipment such as Eye protection 
and hearing protection is recommended. 

● 

Prevent unintentional starting. Ensure the switch is 

in the off-position before connecting to power source, 
picking up or carrying the tool. 

● Remain alert at all times! Never use the appliance 
when you are distracted or don’t feel well. 

 

● Do not carry the appliance by the power cord and 

never hang it up by the power cord. Always route the 
power cord away from the appliance to the rear

. Keep 

cord away from heat, oil, sharp edges and moving 
parts. Do not use if the cord is worn or damaged. 

● The compressor and hoses can get very hot during 

operation. Touching them can cause burns. 

● 

When removing the quick coupler, always hold the 

hose coupling fi rmly to avoid injury caused by the 
hose flying off. 

● 

The appliance vibrates during operation. Therefore, 

always put it down during operation.  
 

 

3. INTENDED USE 

 

4. SAFETY 

 

Summary of Contents for MP7950

Page 1: ... Power MP7950 12V DC 8A 100 Watt 12L Min 160 psi 75 2 dB A 95 2dB A 1 ON OFF main switch 2 LCD display 3 Handle 4 button 5 button 6 Unit shift button 7 Compressed air hose 8 Quick Coupler 9 12 Vdc vehicle connector 10 Tyre connector 11 Ball needle connector 12 Inflatables connnector 13 LED light 1 TECHNICAL SPECIFICATION 2 PRODUCT SPECIFICATION ...

Page 2: ...ed Avoid using the compressor at temperatures below 5 degrees Never leave the compressor unsupervised while it is in use Ensure that the ON OFF switch is turned off when connecting to the power supply Caution Operate the compressor only for a short time The appliance may overheat if operated continuously for longer than 10 minutes Switch the appliance off immediately and allow it to cool down for ...

Page 3: ...upler is correctly fitted to the item to be inflated To start the inflator press the main switch 1 to the on position When the item is inflated as required or to stop the inflator at any time press the main switch 1 to the off position SETTING THE AUTOMATIC SHUT OFF PRESSURE Note The LCD will only show inflation pressures when the inflator is being used To switch between the different units psi ba...

Page 4: ...om damage during transport it is delivered in sturdy packaging Most of the packaging materials can be recycled Take these materials to the appropriate recycling locations Take your unwanted machines to your local dealer Here they will be disposed of in an environmentally safe way Discarded electric appliances are recyclable and should not be discarded in the domestic waste Please actively support ...

Reviews: