background image

 

QUICK START 

 

Before use, ensure the device is sufficently charged and check the manufacturer

s recommended pressure for 

the item you are inflating. 

 

Ensure the air hose is securely screwed into the compressor 

 

Select the appropriate adaptor for the item you are inflating and screw into the air chuck. 

 

Connect the adaptor into the valve of the item you are inflating. 

 

To activate the compressor press the SET button on the display. 

 

Wait approximately 2-3 seconds for the display to show a pressure before attempting to start the compressor. 

 

The current pressure will be displayed, unit of measure can be changed (psi, bar, kPa, kg/cm2) by pressing the 

“SET” button.

 

 

Press the On/Off button to start the compressor. 

 

The compressor will run continuously until the On/Off button is pressed again. 

 

The LED light will illuminate whilst the compressor is in use. 

 

SETTING THE AUTOMATIC SHUT-OFF PRESSURE 

 

The default set pressure is 35PSI.

 

 

Note: 

The LCD will only show inflation pressures when the compressor is connected to a valve.  

 

To switch between the different units (psi, bar, kPa, kg/cm2), press 

the “SET” button

 (FIG 4) until the 

required units are displayed.

 

 

Press the “

-

“ or “+” button to choose the desired value. Holding the “

-

“ or “+” button will accelerate the 

numerical change. 

 

 

Once the desired value has been selected the screen will flash 3 times and the pressure will be set. Note: the 
display value will revert to 0.0 until the compressor is being used.

 

 

Connect the adaptor into the valve of the item you are inflating. 

 

Press the On/Off trigger button to start the compressor. 

 

When the item to be inflated has reached the preset value the unit will automatically turn off. 

 

To stop the compressor at any time press the On/Off button again. 

 

NOTES: 

 

The compressor will ‘sleep’ after 30 

seconds of inactivity. The digital display will be blank during sleep mode. 

To re-activate the compressor press the SET button on the display. 

 

You may notice the actual pressure reading may drop after a couple of seconds, this is normal. 

 

In automatic shut off mode the compressor will inflate approx 1.5 PSI over the pre set value before it cuts out 
to compensate for pressure fluctuations during the inflation process 

 
                                   

 

 

 

 

   

FIG 4 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MP7955

Page 1: ...ating manual fully and abide by all safety instructions when using this device Keep these instructions for future reference When passing the device on to others be sure to also include all documentati...

Page 2: ...ly use the accessories supplied with the compressor Do not use if there is any signs of damage to the product or if any switchgear is unoperational Lithium Ion safety instructions Only ever recharge t...

Page 3: ...FIG 1 This box contains 1 x Compressor 1 x 2 000mAh lithium ion battery 1 x A C charger 1 x Ball adaptor 1 x Small inflatable adaptor 1 x Large inflatable adaptor FIG 1 PRODUCT SPECIFICATION COMPONENT...

Page 4: ...ed by the illumination of LED s on the rear of the battery Once all 3 LED s are permanently illuminated the charge process is complete Fully charge the battery at least once every 3 months to ensure t...

Page 5: ...sor is connected to a valve To switch between the different units psi bar kPa kg cm2 press the SET button FIG 4 until the required units are displayed Press the or button to choose the desired value H...

Page 6: ...SB cable not included into the 5V 1A USB outlet into the rear of the battery Connect to your device FIG 5 Push the power button which is located underneath the A C charging inlet as shown below FIG 6...

Page 7: ...waste Please actively support us in conserving resources and protecting the environment by returning this appliance to the collection centres if available DECLARATION OF CONFORMITY We declare under ou...