15

Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible 

portion of the mobile home structure and must not terminate 

beneath the mobile home. Terminate the exhaust vent outside.

 

Determine vent path:

 

Select route that will provide straightest and most direct 

path outdoors.

 

Plan installation to use fewest number of elbows and turns.

 

When using elbows or making turns, allow as much room 

as possible.

 

Bend vent gradually to avoid kinking.

 

Use as few 90° turns as possible.

Vent System Chart

Number of

90° turns 

or elbows

Type 

of vent

Box/louvered 

hoods

Angled 

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

The Vent System Chart provides venting requirements that 

will help achieve best drying performance.

Determine vent length and elbows needed for best 

drying performance:

 

Use following Vent System Chart to determine type of vent 

material and hood combinations acceptable to use.

NOTE:

 Do not use vent runs longer than those specifi ed 

in Vent System Chart. Exhaust systems longer than those 

specifi ed will:

 

Shorten life of dryer.

 

Reduce performance, resulting in longer drying times 

and increased energy usage.

NOTE:

 Side and bottom exhaust installations have a 90º turn 

inside the dryer. To determine maximum exhaust length, add 

one 90º turn to the chart.

Install Vent System

12" min.

(305 mm)

12" min.

(305 mm)

1. 

Install exhaust hood

Install exhaust hood and use caulking compound to seal 

exterior wall opening around exhaust hood.

Venting Kits

For more information, call 

1-800-344-1274

, or visit us 

at 

www.maytagreplacementparts.com

.

Part Number 

Descriptions

8171587RP 

0"–5" Metal vent periscope

4396037RP 

0"–18" Metal vent periscope

4396011RP 

18"–29" Metal vent periscope

4396014 

29"–50" Metal vent periscope

4392892 

In-wall metal DuraVent™ periscope

279818 

4-way vent kit – white

W10186596 

4-way vent kit – universal grey

4396028 

Sure Connect™ venting kit

 

(over-the-top installation)

4396009RP 

5' Universal connect vent, fl exible dryer venting

4396010RP 

6' SecureConnect™ vent, fl exible dryer venting

4396013RB 

Dryer vent installer’s kit

4396033RP 

5' fl exible dryer venting with clamps

4396727RP 

8' fl exible dryer venting with clamps

4396004 

Dryer offset elbow

4396005 

Wall offset elbow

4396006RW 

DuraSafe™ close elbow

4396007RW 

Through-the-wall vent cap

4396008RP 

4" steel dryer venting clamps – 2 pack

8212662 

Flush mounting louvered vent hood, 4"

Summary of Contents for MEDP575G

Page 1: ...NSTALLATION INSTRUCTIONS 27 WIDE MODELS U S A ONLY Para obtener acceso al manual de uso y cuidado en español o para obtener información adicional acerca de su producto visite www maytag com Tenga listo su número de modelo completo Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta Table of Contents INSTALLATION NOTES Date of purchase _________________________...

Page 2: ...2 DRYER SAFETY ...

Page 3: ...Phillips screwdriver Wire stripper direct wire installations Tin snips new vent installations Adjustable wrench that opens to 1 25 mm or hex head socket wrench Vent clamps 1 4 6 mm nut driver recommended Utility knife Tape measure Pliers Level Caulking gun and compound for installing new exhaust vent Putty knife Parts supplied Leveling legs 4 Parts package is located in dryer drum Check that all p...

Page 4: ...ilding inspector Installation clearances The location must be large enough to allow the dryer door to open fully Parts needed Check local codes Check existing electrical supply and venting and read Electrical Requirements and Venting Requirements before purchasing parts Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased yo...

Page 5: ...m Required Spacing Additional spacing recommended Recessed Area Installation Closet Installation Mobile home Additional installation requirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 28...

Page 6: ...ecified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path...

Page 7: ...n Requirements ELECTRICAL CONNECTION Power Supply Cord Electrical Connection Options 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection section Then go to Venting Requirements 3 wire direct connection Go to 3 Wire Direct Wire Connection section Then go to Venting Requirements 4 wire direct connection Go to 4 Wire Direc...

Page 8: ...ief screws just enough to hold the two clamp sections C together 1 Attach power supply cord strain relief Power supply cord strain relief Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection on page 9 Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 Wire Power Supply Cord Connection on page 9 If your outlet looks like this Fire Hazard Use 10 ga...

Page 9: ...re connections 3 Wire Power Supply Cord Connection IMPORTANT Use where local codes permit connecting cabinet ground conductor to neutral wire 4 Connect remaining wires Connect remaining wires to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements A F Connect ground wir...

Page 10: ...4 19 mm UL Listed strain relief Put the threaded section of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads A B C 1 Attach direct wire strain relief Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet ...

Page 11: ... wire green or bare F of direct wire cable to external ground conductor screw A Tighten screw Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 5 Connect ...

Page 12: ...eze hooked end together Tighten screw 3 Connect neutral wire 1 Prepare to connect neutral ground wire and neutral wire A E B Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A E B C Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw 3 Connect rema...

Page 13: ...l vent Recommended for best drying performance and to avoid crushing and kinking Flexible metal vent Acceptable only if accessible to clean Must be fully extended and supported in final dryer location Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4 ft 2 4 m...

Page 14: ...tional side exhaust outlet A B C A Standard rear offset exhaust installation B Left or right side exhaust installation C Bottom exhaust installation Optional exhaust installations Exhaust can be converted out the right side left side or through the bottom 4 way vent kit Each kit includes step by step instructions For ordering information see Venting Kits Alternate installations for close clearance...

Page 15: ...hart Exhaust systems longer than those specified will Shorten life of dryer Reduce performance resulting in longer drying times and increased energy usage NOTE Side and bottom exhaust installations have a 90º turn inside the dryer To determine maximum exhaust length add one 90º turn to the chart Install Vent System 12 min 305 mm 12 min 305 mm 1 Install exhaust hood Install exhaust hood and use cau...

Page 16: ...fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp 2 Move dryer to final location Move dryer to final location Avoid crushing or kinking vent After dryer is in place remove corner posts and cardboard from under the dryer 1 Level dryer Not Level LEVEL Not Level Check levelness of dryer from side to side Repeat from front to back NO...

Page 17: ...amp cloth to remove any dust Read Dryer Use in your Use and Care Guide Set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supply is on Household fuse is intact and tight or circuit brea...

Page 18: ... door over towel on dryer grasp sides of outer door and lift to separate it from inner door NOTE Do not pry apart with putty knife or screwdriver Do not pull on door seal or plastic door catches 5 Remove screws from door Remove screws attaching hinges to door 4 Remove screws from hinges 9 Remove and transfer plugs Remove the four screws that attach two plugs on the left side Transfer plugs to oppo...

Page 19: ...ple may be needed to reinstall door Insert screws into the bottom holes on left side of dryer cabinet Tighten screws halfway Position door so large end of door hinge slot is over screws Slide door up so screws are in bottom of slots Tighten screws Insert and tighten top screws in hinges TROUBLESHOOTING See the Use and Care Guide or visit our website and reference Frequently Asked Questions to poss...

Page 20: ...NOTES W11045669A W11045670A SP 05 17 TM 2017 Maytag All rights reserved ...

Reviews: