Clearing Diagnostic Codes
To clear the diagnostic code list press
Air Fluff
and
Hidden
key for 3 seconds while in diagnostic mode.
Diagnostic Codes
Code Description Trigger
Action
Taken
1
Dryer Thermistor
Short Sensed
The
thermistor
resistance is
very low,
with a
temperature
> 175
degrees.
Check for:
-
Clogged lint
screen.
-
Restricted
vent system.
Failed thermistor.
2
Thermistor Open
Sensed
The
thermistor
resistance is
very high
Check for:
-
Low ambient
temperature in
room (Below
50 F/10 C).
º
º
-
Outside vent
damper is stuck
open in
wintertime.
Loose or open wire
terminals
3
Door Circuit
Failure
Invalid state
for more
than 256
milliseconds
Check for:
- Loose or open wire
terminals in Door
Sense circuit.
4
Possible motor
transistor error
If either
motor
transistor is
seen open or
shorted
during
startup
Check for:
-
Loose
connections in
motor circuit.
-
Run System
Check Mode
and check the
motor relay
function.
-
If relay
functions,
disregard the
diagnostic
code.
If relay does not
function, replace
machine control
board.
5
Not Used
6
Non Volatile
Memory
Problem
Detected
with integrity
of
parameters
stored in
EEPROM
memory.
Disregard
8
Stuck Key
A key is
sensed to be
pressed
more than
75 seconds,
the key shall
be assumed
to be stuck.
Run membrane pad
check and replace
console w/membrane
pad if necessary.
System Check Mode
While in Service Mode, pressing the
Air Fluff
and
Signal (+)
keys for 3 seconds, will put the dryer into the
System Check mode and "
SC
" will display. The
following table lists the various functions based on the
keys being pressed.
System Check Mode Table
Key Pressed:
Function
Performed
Sensor Dry
Enable sensor
dry circuit (sense
dry LED) when
short circuit is
detected across
the sensor bars
the normal dry
LED will turn on
.
Start/Pause
Cycles the motor
relay on/off.
When the motor
is running the
start/pause LED
is on.
Dry Temp (^)
If motor is
running, cycles
the heater
on/off.
When the heater
is regular temp
LED is on.
Dryness level (^)
View tumbler