background image

Troubleshooting Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless  
testing requires power. 

16026775 

September 2006 

 

©2006 Maytag Services

 

4

Clearing Diagnostic Codes 
 

To clear the diagnostic code list press 

Air Fluff

 and 

Hidden

 key for 3 seconds while in diagnostic mode. 

 

Diagnostic Codes 

Code Description  Trigger 

Action 

Taken 

Dryer Thermistor 
Short Sensed 

The 
thermistor 
resistance is 
very low, 
with a 
temperature  
> 175 
degrees. 

Check for:   

Clogged lint 
screen. 

Restricted 
vent system.

 

Failed thermistor. 

Thermistor Open 
Sensed  

The 
thermistor 
resistance is 
very high 

Check for:  

Low ambient 
temperature in 
room (Below 
50 F/10 C). 

º

º

Outside vent 
damper is stuck 
open in 
wintertime. 

 Loose or open wire 

terminals 

Door Circuit 
Failure 

Invalid state 
for more 
than 256 
milliseconds

 

Check for: 

-   Loose or open wire 

terminals in Door 

Sense circuit. 

Possible motor 
transistor error 

If either 
motor 
transistor is 
seen open or 
shorted 
during 
startup 

Check for: 

Loose 
connections in 
motor circuit. 

Run System 
Check Mode 
and check the 
motor relay 
function. 

If relay 
functions, 
disregard the       
diagnostic 
code. 

If relay  does not 

function, replace 

machine control 

board. 

Not Used 

 

 

Non Volatile 
Memory 

Problem 
Detected 
with integrity 
of 
parameters 
stored in 
EEPROM 
memory. 

Disregard 

Stuck Key 

A key is 

sensed to be 
pressed 
more than 
75 seconds, 
the key shall 
be assumed 
to be stuck.  

 Run membrane pad 

check and replace 

console w/membrane 

pad if necessary. 

 
 
 
 

System Check Mode 

While in Service Mode, pressing the 

Air Fluff 

and 

Signal (+) 

keys for 3 seconds, will put the dryer into the 

System Check mode and "

SC

" will display. The 

following table lists the various functions based on the 
keys being pressed. 

 

System Check Mode Table 

 

Key Pressed: 

Function 

Performed 

Sensor Dry  

Enable sensor 
dry circuit (sense 
dry LED) when 
short circuit is 
detected across 
the sensor bars 
the normal dry 
LED will turn on

.

 

Start/Pause 

Cycles the motor 
relay on/off. 
When the motor 
is running the 
start/pause LED 
is on. 

Dry Temp  (^) 
 

If motor is 
running, cycles 
the heater

on/off. 

When the heater 
is regular temp 
LED is on. 

Dryness level (^)

 

View tumbler 
temperature in 
Celsius. 

 

 

Summary of Contents for CDE4205A SERIES

Page 1: ...an for servicing or repair of this unit Refer to Service Manual 16023110 for detailed installation operating testing troubleshooting and disassembly instructions CAUTION All safety information must be followed as provided in Service Manual 16023110 WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power ...

Page 2: ...s flex ductwork installed Poor makeup air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower impeller bound check for foreign material in blower area Customer overloading dryer Check clothing labels for fabric content and cycle selected Clothes too wet due to insufficient spin out by washer Will Not Shut Off Short in Sensor Circuit Check Membrane Pad Check Electronic Cont...

Page 3: ...agnostic codes only The key will be referred to as hidden key and is located under the surface of the last character y in the brand nam e Diagnostic Tests The following table lists the various tests available while in the Service M ode Key Press Special Test Function Hidden Key See Control Diagnostics Dry Temp D isplay diagnostic codes Sequence thru diagnostic codes Dryness Level View tum bler te ...

Page 4: ...orted during startup Check for Loose connections in motor circuit Run System Check Mode and check the motor relay function If relay functions disregard the diagnostic code If relay does not function replace machine control board 5 Not Used 6 Non Volatile Memory Problem Detected with integrity of parameters stored in EEPROM memory Disregard 8 Stuck Key A key is sensed to be pressed more than 75 sec...

Page 5: ... J7 13 Time J7 10 J7 13 Time J7 9 J7 13 Dry Temp J7 11 J7 14 Dry Temp v J7 10 J7 14 Dryness level J7 12 J7 14 Dryness level v J7 19 J7 14 Hidden Key J7 11 J7 15 Wrinkle Prevent J7 9 J7 15 Air Fluff J7 10 J7 15 Start Pause J7 11 J7 16 Signal J7 12 J7 15 Off J7 9 J7 16 Signal J7 12 J7 16 Motor Schematic es pt on Connec Pin Co Pin ol age om en Heater Relay Internal Output P1 BB1 1 120VAC LI Board inp...

Page 6: ...Diagram and Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power 16026775 September 2006 2006 Maytag Services 6 ...

Reviews: