Page 1: ...0 240 or a 120 208 volts 60 Hz AC branch circuit Connect only to a 3 wire 120 240 volt power supply the neutral conductor is not required for the operation of the appliance The potential at the power supply electrical connections shall be 150 volts to ground or less The flexible armored conduit supplied with the unit must be connected to an approved electrical junction box by means of an approved ...

Page 2: ...ded thehazard canbereduced byinstalling arange hoodthat projectshorizontally a minimum of 5 inches beyond thebottom ofthecabinets CAUTION SOME CABINETSAND BUILDING MATERIALS ARENOTDESIGNED TOWITHSTAND THE HEATPRODUCED BY THE NORMAL SAFE OPERATION OF A LISTEDAPPLIANCE DIS COLORATION ORDAMAGE SUCH ASDELAMINA TION MAYOCCUR COUNTER TOP BASE If cooktop is to be secured to countertop remove main top and...

Page 3: ...0 VOLTS ELECTRICAL SERVICE 3 3 8 MIN PLUS CLEARANCE INSIDE FOR RIGHT ANGLE CONDUIT AND WIRE FIGURE2 30 Smoothtop Ceramic Cooktop 6 WIRE LEADS 2 3 4 DEPTH FRONT OF UNIT 3 8 FLEXIBLE CABLE 48 LONG FURNISHED AND INSTALLED BY MANUFACTURER CONNECT TO 240 120 VOLT ELECTRICAL SERVICE 29 7 16 2 I 8 MIN 20 7 16 RGURE3 4 I 4 CLEARANCE INSIDE FOR RIGHT ANGLE CONDUIT AND WIRE ...

Page 4: ...vado de CA de 60 Hz 120 240 6 120 208 voltios de tres hilos Debe conectarse solamente a suministros electricos de 120 240 voltios de 3 hilos no se necesita un conductor neutro para el funcionamiento del electrodomestico El voltaje en las conexiones electricas del suministro electrico debera ser de 150 voltios a tierra o menos El conducto blindado flexible que se suministra con la unidad debe estar...

Page 5: ...ente cuando menos 5pulgadas masque losgabinetes inferiores PRECAUClON ALGUNOS GABINETES Y MATERIALES DE CONSTRUCCION NO ESTAN DISENADOS PARA SOPORTAR ELCALOR QUESE PRODUCEDURANTE LA OPERACION NORMAL SEGURA DEUNELECTRODOMESTICO INDtCADO PODRiA OCURRIR DECOLORACION O DANOS TALESCOMO LAPERDIDA DELLAMINADO SUPERFICIE DEL MOSTRADOF _ GABINETE Si la superficie se va a asegurar al mostrador quite la part...

Page 6: ... 3 3 8 MINIMAS M kS EL ESPAClO LIBRE ADENTRO PARA OBTENER EL kNGULO CORRECTO DEL CONDUCTOR Y DEL ALAMBRE FIGURA2 Superficie para cocinar lisa de ceramica de 30 CONDUCTOR DEL ALAMBRE DE 6 2 3 4 DE PROFUNDIDAD FRENTE DE LA UNIDAD CABLE FLEXIBLE DE 3 8 DE 48 DE LARGO PROVISTO E INSTALADO POR EL FABRICANTE CONECTADO AL SERVlClO ELI_CTRICO DE 240 120 VOLTIOS 29 7 16 2 I 8 MIN 20 7 16 FIGURA3 4 1 4 DE E...

Page 7: ...tue de 2 conducteurs isoles et d un fil de terre nu et prevu pour une utilisation sur un circuit secondaire alternatif trifilaire de 120 240 V ou 120 208 Vet 60 Hz Raccorder a une alimentation trifilaire de 120 240 V uniquement le conducteur neutre n est pas necessaire au fonctionnement de I appareil Le potentiel au niveau des raccordements au secteur sera de 150 V a la terre maximum Le conduit fl...

Page 8: ...voirdesarmoires au dessus de la plaque de cuisson lesrisques peuvent etrereduits enposant unehotte quidepasse d unminimum de5podubasdesarmoires ATTENTION CERTAINES ARMOIRES ET CERTAINs MATI_RIAUX DE CONSTRUCTION NE SONT PAS CONOUS POUR SUPPORTER LA CHALEUR PRODUITE LORS DU FONCTIONNEMENT NORMAL D UN APPAREIL UNE DISCOLORATION OU DES DI_GATS TELS QUE LA DI_LAMINATION PEUVENT SE PRODUIRE DESSUS DU C...

Page 9: ...9 CM ARRONDI TYP DEGAGEMENT DE 8 6 MM k L INTERIEUR POUR LE CONDUIT ANGLE DROIT ET LE FÁL FIGURE2 Plaque de cuisson en vitroceramique de 76 2 cm 53 3 CM MIN 76 2 CM MIN FILS CONDUCTEURS DE 15 2 CM 7 CM MIN DEVANT DE LA PLAQUE 74 8 CM MIN 5 5 CM MIN C _ BLE FLEXIBLE DE 9 5 MM DE DIAM TRE ET 121 9 CM DE LONG FOURNI ET POSE EN USINE RACCORDER k UNE ALIMENTATION ELECTRIQUE DE 240 120 V C21 695 DEGAGEM...