8
Electrical Requirements
■
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
Venting Requirements
VENTING
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT:
Observe all governing codes and ordinances.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
■
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
■
Do not use plastic or metal foil vent.
Rigid metal vent:
■
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent:
(Acceptable only if accessible to clean)
■
Must be fully extended and supported in final dryer location.
■
Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance.
■
Do not install in enclosed walls, ceilings, or floors.
■
The total length should not exceed 7
3
/
4
ft. (2.4 m).
NOTE:
If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal
or flexible metal vents. Review “Vent System Chart” and, if
necessary, modify existing vent system to achieve best drying
performance.
W10486878Av3.indd 8
3/30/12 3:06 PM
Summary of Contents for MGDX5SPAW
Page 2: ...2 DRYER SAFETY ...
Page 3: ...3 ...
Page 19: ...19 SEGURIDAD DE LA SECADORA ...
Page 20: ...20 ...