12
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center,
silver-colored terminal block screw (B). Tighten screw.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
now, go to Venting
Requirements.
ImPoRTAnT:
You must verify with a qualified electrician that this
grounding method is acceptable before connecting.
optional External Ground for
3-Wire connection
(
Power Supply cord Shown)
2.
connect neutral ground wire and
neutral wire
C
E
B
1.
Prepare to connect neutral ground
wire and neutral wire
E
B
A
3.
connect remaining wires
4.
connect remaining wires
4.
connect external ground wire
G
A
Remove center, silver-colored terminal block screw (B).
Remove neutral ground wire (E) from external ground
conductor screw (A).
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
now, go to Venting Requirements.