Basic Climate Control
A/C System
Accumulator / Drier
•
The accumulator / drier serves a similar function to that of the receiver / drier. One
difference is the location in the A/C circuit. The accumulator / drier is located between
the evaporator and the compressor. Vehicles equipped with a fixed orifice may, under
certain operating conditions, allow liquid refrigerant to exit the evaporator. Because of
this, the accumulator / drier also functions as a second evaporator to ensure that no
liquid refrigerant is passed on to the compressor. For this reason, the gaseous
refrigerant is drawn from the top of the accumulator / drier.
L1005_040
1
Inlet from evaporator
5
Compressor oil
2
Outlet to compressor
6
Filter screen
3
Connection for low pressure switch
7
Pick up tube
4 Desiccant
8 Baffle
Curriculum Training
03-27
Summary of Contents for CT-L1005
Page 1: ...Training Manual Basic Climate Control CT L1005...
Page 20: ...Fundamentals Basic Climate Control Notes 02 14 Curriculum Training...
Page 52: ...A C System Basic Climate Control Notes 03 32 Curriculum Training...
Page 66: ...List of Abbreviations Basic Climate Control Notes 06 2 Curriculum Training...