Video Intercom Vandal-Resistant Door Station
·
User Manual
30
Figure 7-15
Set the Access Control Parameters
2.
Set the door No., and the door-unlocked duration.
Note:
The door-unlocked duration varies from 1s to 255s.
The door station, instead of the doorphone, supports configuring the access control
parameters.
I/O Input/Output
Purpose:
I/O input/output refers to the Alarm In terminal and the Alarm Out terminal. You can
connect external devices to the door station via these terminals. The door station has 1
Alarm In terminal (AI), and 1 Alarm Out terminal (NO/COM/NC).
Steps:
1.
Enter the IO input/output settings interface:
Configuration > Video Intercom > IO
Input/Output.
Figure 7-16
Set the IO Input/Output
2.
Set the input mode: Disabled, Exit Button, Door Status, Custom.
Disabled:
The function of the AI terminal is disabled.
Exit Button:
The AI terminal supports connecting to the exit button.