28
10. Exchanging Solenoid Unit
1) Exchanging Solenoid Assy. of Suction Section.
11. Replacing Separator Rubber
1) Replacing Separator Rubber at Paper Separation Section
It should be done, after Suction Assembly is removed per Section 10 above.
After Separator Rubbers are exchanged to new, adjust
that gap between Separator Rubber and Suction Belt
leaves approximately 0.5mm paper path gap.
Solenoid Unit as supplied.
Remove 2 Solenoid Fixing
Screws.
Solenoid unit is removed.
Loosen M4
Nut and
remove
Plunger
Assy.
After Solenoid
Unit is
exchanged to
new, manually
move linkage per
arrow mark and
confirm that it
moves smoothly.
Remove Front Stopper Wall
by removing 3 screws.
IMPORTANT:
Both Two Separators must
be replaced at one time.
Bottom edge of Separator
Rubber is leveled to the
Nipple.
Suction Belt
Front Stopper Wall
0.5mm
Separator