28
(1) Remove the paper feed tables and auxiliary tables. While holding the paper feed shaft, push it in to
the left, then pull it toward the front. If the paper feed rollers are dislocated, correct their positions;
the center rubber roller should be located at the center of the separator.
(2) After removing the paper feed shaft, clean its three rubber rollers using a cloth dampened with
cleaning fluid special for the collator (option). Clean the separator too, leaving it mounted on the
machine while doing so.
(3) Install the paper feed shaft in the way reverse to how it was removed.
Note
Should trouble such as double feed, no feed, etc. occur after cleaning, the rubber paper feed rollers and
separator are worn. Replace them with new ones referring to the previous page. When the paper feed
rubber rollers are replaced, mount them on the paper feed rollers holders so that the white dot of the rubber
rollers is on the right-hand side. In addition, after mounting the paper feed rollers on their holders, roll them
on a flat surface such as a desktop to make sure they are mounted horizontally. If mounted askew, problems
like paper feed failure or double feed may occur. Use a flat head screwdriver to remove the separator. Be
watchful of the paper detection wire when replacing the feed rollers.
・
Cleaning the exterior
Wipe off any stains using a damp cloth.
Remarks
Do not use solvent cleaning liquids as they may cause discoloring.
6.3 Consumables
The collator’s paper feed rollers (CU 145231) and separator rubber (UC 145181) are consumable. Contact
your dealer when they need replacing.
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920