MC100
Mobile programmable gateway
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
24
11.2 Ethernet-Interface (All)
Port
Signal
Description
1
TD+
Transmit plus
2
TD-
Transmit minus
3
RD+
receive plus
4
No function
Internal 100nF against GND
5
No function
Internal 100nF against GND
6
RD-
Receive minus
7
nc
8
Shield
Internal shielding
LED
yellow
SPEED
1 Blinks: Led Blinks once = 10Base link
2 Blinks: Led Blinks twice = 100Base link
LED green
ENWAYEN
ON: Network link has been established
Blinking: Network activity has been detected
11.3 Power supply (all)
Connection to an AC power supply must be made by using a suitable power supply unit.
The DC voltage must be between 8 and 30V.
Port
Description
POW -
Power supply, negative connection
POW +
Power supply, positive connection