MC100
Mobile programmable gateway
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
16
9.6 Online
‐
Test
Navigate to the menu item "Network" and "Diagnostics". Click on the "PING" button under
"Network Utilities". The selected server on the Internet should answer with PING times.
9.7 Internet access
After successfully logging into the mobile network, you can now connect to the Internet
using your browser. To do this, open the browser on your PC and enter a URL known to
you in the address field (e.g. www.mc-technologies.net).
9.8 Access via SSH
To access the Linux system of the MC100, you must connect to the same IP address
(default: 192.168.2.1) as the web interface.
The following access data are required:
User:
root
Password: In delivery state no password is necessary here
To secure your MC100
change the password by entering "passwd" under SSH
.
9.9 Command Line Interface
Open the Command Prompt to login your device:
1. Type: ssh root@192.168.2.1
2. Type the password.
Command
Use to
mcinfo info
Print general information about the modem.
mcinfo mobile
Print information about mobil communication status.
mcinfo gpio
Print information about external GPIO module pins.